Yaskawa E7 Fault Codes 2
CPF03 - EEPROM Fault
Description: EEPROM fault, check sum not valid. This could be due to noise or spikes on the control circuit input terminals.
Solution: Perform a factory initialization. Cycle power off and on to the Drive. If the issue persists, replace the control board.
CPF04 - Internal A/D Converter Fault
Description: CPU internal A/D converter fault due to noise or spike on the control circuit input terminals.
Solution: Perform a factory initialization. Cycle power off and on to the Drive. If the issue persists, replace the control board.
CPF05 - External A/D Converter Fault
Description: CPU external A/D converter fault due to noise or spike on the control circuit input terminals.
Solution: Perform a factory initialization. Cycle power off and on to the Drive. If the issue persists, replace the control board.
CPF07 - ASIC Internal RAM Fault
Description: ASIC internal RAM fault.
Solution: Cycle power off and on to the Drive. If the issue persists due to control circuit damage, replace the Drive.
CPF08 - Watchdog Timer Fault
Description: Watchdog timer fault.
Solution: Cycle power off and on to the Drive. If the issue persists due to control circuit damage, replace the Drive.
CPF09 - CPU-ASIC Mutual Diagnosis Fault
Description: CPU-ASIC mutual diagnosis fault.
Solution: Cycle power off and on to the Drive. If the issue persists due to control circuit damage, replace the Drive.
CPF10 - ASIC Version Fault
Description: ASIC version fault due to control circuit damage.
Solution: Replace the Drive.
CPF20 - Option A/D Error
Description: Option card fault due to option card connector connection fault or option card A/D converter fault.
Solution: Remove all inputs to the option board. Perform a factory initialization. Cycle power off and on to the Drive. Replace the option board and the control board if necessary.
CPF21 - Option CPU Down
Description: Self-diagnosis fault of the communication option card due to noise or spike on the communication line or defective option board.
Solution: Perform a factory initialization. Cycle power off and on to the Drive. Replace the option board and the control board if necessary.
CPF22 - Option Type Error
Description: Communication option card code number fault due to an unrecognizable option board connected to the control board.
Solution: Remove any option boards. Cycle power off and on to the Drive. Perform a factory initialization. Replace the option board and the control board if necessary.
CPF23 - Option DPRAM Error
Description: Communication option card interconnection fault due to an option board not being correctly connected to the control board or an option board that is not made for the Drive being attached to the control board.
Solution: Remove power to the Drive. Connect the option board once more. Perform a factory initialization. Cycle power off and on to the Drive. Replace the option board and the control board if necessary.
EF0 - Communication Option Card External Fault
Description: An external fault condition exists.
Solution: Check for an external condition. Verify the parameters and communication signal.
EF3 - External Fault at Terminal S3
Description: An external fault condition exists connected to a multifunction digital input.
Solution: Eliminate the cause of the external fault condition.
EF4 - External Fault at Terminal S4
EF5 - External Fault at Terminal S5
EF6 - External Fault at Terminal S6
EF7 - External Fault at Terminal S7
Description: External fault at the respective terminal.
Solution: Remove the fault from a multifunction digital input.
FBL - Feedback Loss
Description: This fault occurs when PI Feedback Loss Detection is programmed to fault (b5-12 = 2) and the PI Feedback < PI Feedback Loss Detection Level (b5-13) for the PI Feedback Loss Detection Time (b5-14).
Solution: Verify the Drive is programmed to receive the PI Feedback source signal. Check to ensure the PI Feedback source (e.g., transducer, sensor, building automation signal) is installed and working properly.
GF - Ground Fault
Description: Drive output grounding current has exceeded 50% of the Drive rated output current. This could be due to a motor lead shorted to ground or a defective DCCT.
Solution: Remove the motor and run the Drive without the motor. Check the motor for a phase-to-ground short. Check the output current with a clamp-on meter to verify the DCCT reading.
LF - Output Phase Loss
Description: An open-phase occurred at the Drive output, detected when output current has exceeded a 5% imbalance. This could be due to a broken wire in the output cable, motor winding, loose output terminals, using a motor with a capacity less than 5% of the Drive's maximum motor capacity, or using a low impedance motor.
Solution: Check the wiring to the motor and the motor for a phase-to-ground short. Ensure the motor and Drive capacity are compatible. Add additional impedance if necessary. Adjust parameter E2-03 to a lower value if set incorrectly.
LL3 - Loss of Load Detection 1
Description: Drive output current is less than L6-02 for more than the time set in L6-03, indicating the motor is underloaded.
Solution: Ensure the values in L6-02 and L6-03 are appropriate. Check the application/machine status to eliminate the fault.