Toshiba S7 Fault index

OC1 Overcurrent during acceleration:
Increase the acceleration time or adjust the torque boost level.

OC2 Overcurrent during deceleration:
Increase the deceleration time.

OC3 Overcurrent during constant-speed run:
Reduce the variance of the load conditions.

OCA Phase short circuit:
Main circuit is abnormal; repair the inverter.

OCL Load-end short circuit during start-up:
Check insulation and wiring of the main output circuit or motor.




OP1 Overvoltage during acceleration:
Check power voltage and for excessive current flow.

OP2 Overvoltage during deceleration:
Increase the deceleration time.

OP3 Overvoltage:
Check power voltage and for excessive current flow.

nOFF Undervoltage:
Input voltage is too low; check power supply and wiring.

OL1 Inverter overload trip:
Reduce the load or increase the inverter rating.
OL2 Motor overload trip:

OLr Braking resistor overload trip:
Increase the deceleration time.

OH Overheat trip:
Check ambient temperature and remove the seal if too high.

E Emergency stop:
Operation stops during automatic or remote control.

EOFF Emergency stop acceptance check:
Stop operation by pressing the STOP key twice.

EEP1 EEPROM fault:
Turn off and on the power or repair the inverter.

Etn Automatic tuning error:
Check torque up parameters.

EPH0 Output phase loss:
Check wiring between inverter and motor.

Err.1 Frequency setting signal error:
Separate the frequency setting signals.

Err.2 RAM fault:
Repair the inverter.

Err.3 ROM fault:
Repair the inverter.

Err.4 CPU fault:
Repair the inverter.

Err.5 Communication interruption error:
Check the communication device and wiring.

EtYP Inverter typeform error:
Set the mode to 6 if PCB is replaced.

C Stall prevention alarm:
Adjust acceleration time and torque level.

P Overvoltage alarm:
Increase the deceleration time.

L Overload alarm:
Reduce the load or increase inverter capacity.

HI LO Set value alarm:
Check and reset incorrect set values.

Conditions Displayed on Operation Panel:

- Frequency, 2) parameter display or changes, 3) inverter condition or error.

Keys:

- MON key: Switches between frequency, parameter, and inverter condition.
- ENT key: Stores selected item in the inverter.
- UP/DOWN key: Displays items or changes numeric values.

Display Unit:

- Shows running, inverter condition, or parameter set value.

Modes:

- Operation frequency or error contents,
- Parameter name or set value,
- Inverter condition.

Automatic Functions:

VF-S7 offers automatic acceleration/deceleration, torque boost, and environment setting. May not work for all load conditions.

Displays for Operations:

Symbols indicate LED displays and panel key operations.

+ Toshiba S7 User Manual >>

+ Toshiba S7 Fault index >>

+ Toshiba S7 Fault codes 1 >>

+ Toshiba S7 Fault codes 2 >>

+ Toshiba S7   >> 


+ Toshiba 2 Main page -

+ Used VFD Models

+ VFD Main page -

-

"* The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please do not hesitate to share them with us."  08.03.2013   




Your shopping cart is empty!