6ES7 171-2AA02-0AA0

6ES7 171-2AA02-0AA0 – Siemens LA 724

6ES7 171-2AA02-0AA0 is the LA 724 heater power output for HS 724: 24 channels, 230 V AC, eight outputs per phase and front-accessible channel fuses.

When selecting a spare for heating control, assess heater ratings, cabinet cooling and the existing system’s parts list together. Use the complete order number on the product label.

Role in the system

A 724 parallel bus connects it to the ZA 724 central interface, which handles PROFIBUS-DP communication. Record the central interface’s order number when reviewing the project’s PLC and modules.

Power and cooling requirements

Per-channel power at 230 V AC: 650 W without forced cooling; 1000 W with forced cooling; 1500 W with forced cooling and reduction to 12 channels. Forced-cooling airflow: above 2.5 m/s. Maximum phase current: 32 A per module.

Do not apply the highest wattage to every output as a single unrestricted rating. Calculate the connected load for each phase. During selection, check the airflow path and load distribution as well as whether a fan is fitted.

Comparing models

When comparing 6ES7 171-2AA00-0AA0, check the complete code, connections and the machine’s parts list. The later LA 724i has order number 6BK1700-2BA00-0AA0. A similar name does not establish interchangeability; verify the central interface and system configuration before choosing a replacement.

Checking a used unit

Inspect the label, connectors, fuse holders and signs of overheating. Check the specified fuse type in the relevant manual. Ask which channels were tested, with what load and under what cooling conditions. A working output alone is insufficient evidence that every channel has been checked.

Editor’s Note: When sourcing a spare, keep the central interface’s label, cabinet wiring information and heater ratings alongside photographs of the removed module. These details make it easier to compare a candidate against the machine’s requirements. Also confirm which connectors and other connection parts are included before placing an order.

Manuals and PDF documents

Use the Siemens ET 200 manuals section for documentation. The primary reference is HS 724, 05/2001, Section 2.2. The model comparison uses the order list in HS 724i, 04/2003, Appendix A.

Related topics

Explore other heating-panel components through controllers, temperature sensors and SSR relays. For control hardware, see PLC and HMI and Siemens S7 PLC.

Browse other module groups under ET 200 digital outputs, function and safety modules, special output modules and the special application product index. Assess suitability using each product’s own order number and manual.

Navigation