6ES5 325-0UA11

Siemens 6ES5 325-0UA11 – SIMATIC S5 FOX PG-M Adapter for PG 730 and PG 750

The Siemens 6ES5 325-0UA11 is listed as a FOX PG-M adapter for the PG 730 and PG 750. In Siemens' description of FOX PG-M, an inline adapter lets the programmer monitor serial message frames. Match the connections at both ends and the software to the service setup on the machine.

Cables for direct PG connections

The PG 750-486 manual specifies the 6ES5 734-2BD20 cable for a direct COM1/TTY connection to the PLC. The 734-2BF00 belongs to the same cable family. The catalogue of S5 cables and connectors also includes older codes such as the 731-0BD20, 731-1BD20, 731-1BF00 and 731-1CB00. The 734-0BD20 is for a different PG connection. Match the devices at both ends and the full cable order number.

For a direct connection to an S5-100U with a CPU 100 or CPU 103, or an S5-115U with a CPU 944, follow the PG wiring diagram for that CPU. The PG 730 documentation describes the COM1, TTY and V.24 connections and their requirements. The pin assignment for the exact 325-0UA11 order number could not be confirmed from a Siemens drawing.

CP 530 and other service setups

Siemens' CP 530 manual shows a SINEC L1 monitoring example with a PG 675 and the 6ES5 321-0AA11 adapter. If the system uses a CP 530 3LA11, 3LA12, 7LA11 or 7LA12, read the full order number from the processor label and identify the port being monitored.

The CP 524 and CP 544 communication processors have their own connection diagrams. The PG 511 interface and S5-110A test module serve different maintenance tasks. To sell a 325-0UA11 adapter, send photos of the label and both connection ends to otomasyonavm@gmail.com.

Editor's note

Before buying, ask for photos of the 325-0UA11 label and both ends of the adapter. Record the full PG 730 or PG 750 model as well.

Locate the FOX PG-M software and its original disk or backup. Check that it starts on the programmer version in use.

With the connectors unplugged, look for bent pins, loose shells and any cable added during a previous repair.

Verify the serial interface type and both ports against the machine diagram. Identical connector shapes can carry different electrical signals.

Use a known message frame for the initial monitoring test. Note the time of the test and check whether traffic is captured in both directions.

PDFs and part references

+ Siemens computer link manual (EN) – Section 7.2.4, FOX PG-M monitoring

+ Siemens PG 730 system manual (DE) – Sections 13 and 15, interfaces

+ Siemens PG 750-486 manual (EN) – Section 5.2, direct PG connection

+ Siemens SINEC L1 manual (EN) – Section 3.4, PG 675 and 321 adapter example

+ 6ES5 325-0UA11 FOX PG-M – supplier part listing

+ Siemens S5 PDF archive

Related topics

+ S5 interface modules

+ S5 expansion modules and adapter casings

+ About Siemens S5 PLCs