6ES5 816-0AA11
6ES5 816-0AA11 – OP 396 ASCII Operating System EPROM Submodule
Siemens 6ES5 816-0AA11 is the ASCII operating system submodule for the OP 396 operator panel. It holds the panel's system software for use with SIMATIC S5 controllers and fits into memory receptacle 1 on the OP 396. Siemens specifies 64 Kbytes of EPROM for the panel's operating system memory.
When restoring an operator station, distinguish the system software from the machine application. This EPROM contains the operating system; screens and messages created with COM 396 reside in the user submodule in receptacle 2. Selecting from S5 memory cards by physical appearance alone can therefore lead to the wrong replacement.
Supported S5 systems
For this exact order number, Siemens lists S5-90U, S5-95U, S5-100U, S5-101U, S5-115U, S5-135U with S and R processors or CPU 928, and S5-150U. When checking an S5-90U installation or other S5 CPU groups, review both the operating system selection and the panel connection. The submodule installs in the OP 396, rather than in the PLC rack.
The OP 396 requires a suitable power supply adapter when connected to S5-90U, S5-135U or S5-150U systems. Check the controller port when selecting a 6ES5 984-2UA11 adapter and the appropriate S5 connecting cable. The manual lists the separate 6ES5 816-0AB11 operating system option for S5-155U support; do not extend that support to 0AA11.
Operating system versus user memory
For the OP 396 user configuration, Siemens lists the 8 Kbyte 6ES5 375-0LA15, 16 Kbyte 6ES5 375-0LA21 and 32 Kbyte 6ES5 375-0LA41 EPROMs. These are user submodules for receptacle 2 and do not replace the 816-0AA11 operating system submodule.
The listed EEPROM options for user configuration include the 8 Kbyte 6ES5 375-0LC31 and 16 Kbyte 6ES5 375-0LC41. When comparing memory types, verify the contents, capacity and intended receptacle separately. Purchasing the operating system submodule alone does not provide the machine's screen configuration.
COM 396 version and communication checks
OP 396 operating system V2.0 and later cannot directly run user submodules created with COM 396 V1.0. Operating system V1.0 also rejects configurations produced with COM 396 V2.0 and later. The manual describes conversion of older configuration records using COM 396 V2.0. Before replacement, record the operating system version shown at power-up; do not infer it from the order number alone.
The panel connects to the PLC using TTY / 20 mA, 9600 baud and AS511. These specifications describe the OP 396 connection, rather than a separate field terminal or communication port on the 816-0AA11. Keep the role of this operating system submodule distinct from that of S5 interface modules and S5 communication modules.
During commissioning, retain a common record for the SIMATIC S5 CPU system, operator panel, user memory and connection accessories. When documenting S5 modules, record the complete order number, label photograph, hardware revision and observed software version separately to make subsequent fault tracing easier.
Editor’s Note
Start with a clear label photograph and a record of the power-up version. With older S5 accessories, an identical housing is a poor basis for a purchase. Check the 0AA11 suffix, the observed software version and the panel's existing user memory together.
Before removing a module from a working panel, arrange a backup of the screen project and user memory. In Siemens S5 maintenance, losing the original messages and settings can create more work than sourcing the replacement. Document the working combination first.
Disconnect power before removing or inserting the submodule. Isolate the panel and any adapter supply, then inspect the contacts for bending, corrosion or signs of forced insertion. Use appropriate electrostatic precautions and retain the protective plastic cover.
Where possible, test a used submodule in a known working OP 396 with a version-compatible user submodule. Check that startup completes, configured text is displayed correctly and a known test value can be read from the PLC. An illuminated display alone is insufficient evidence of correct operation.
If the panel starts but cannot reach the PLC, check the cable, adapter, controller port and user configuration before condemning the EPROM. Use a controlled test address instead of changing production settings, and record exactly what the test demonstrated.
OtomasyonAVM resources and PDFs
For the host panel, see the 6ES5 396-0UA11 OP 396 page. For application memory, browse the S5 memory card section.
+ Shared SIMATIC S5 PDF and system manual archive. The English OP 396 manual that lists this exact order number is linked in the external references below.
Related topics
+ EPROM memory and its differences from other memory types.
+ S5 cables and connectors; 984-2UA11 adapter option for the OP 396.
Browse SIMATIC S5
S5 accessories · S5 memory cards · SIMATIC S5 CPUs and systems · Siemens S5 PLCs · Siemens second-hand equipment
Siemens and external references
Siemens SIMATIC S5 OP 396 Operator Panel Operating Instructions – EWA 4NEB 810 1288-02a (English PDF). Relevant sections: 1.1 version compatibility, 2.2 interfaces, 2.3 memory submodules, 2.4 specifications and 3 getting started.