6ES5 981-0GA11
Siemens 6ES5 981-0GA11 – Long-Rack Mounting Kit with Cable Duct
The Siemens 6ES5 981-0GA11 is a cable duct and bracket kit for 483 mm long mounting racks in the SIMATIC S5-115U/H/F range. The two brackets support the fan subassembly below the rack. The duct clips onto the brackets and routes field cables to the side. Siemens catalogue ST 50 gives an approximate combined weight of 0.5 kg for the duct and brackets.
Matching the fan and rack
Siemens lists the 0GA11 kit for the 6ES5 981-0HA11 (115/230 V AC) and 6ES5 981-0HA21 (24 V DC) long-rack fan subassemblies. Those voltage ratings apply to the fan subassemblies. The 0GA11 kit is a passive mounting accessory.
Check the full part number on the central rack. Long versions include the CR 700-1, 6ES5 700-1LA12 and CR 700-2, 6ES5 700-2LA12 for S5-115U, and the CR 700-2F, 6ES5 700-2LA22 for S5-115F. For expansion racks, compare the nameplate with the ER 701-1, ER 701-2, ER 701-3 or the S5-115H 6ES5 701-3LH11.
For 353 mm short racks such as the CR 700-0, 6ES5 700-0LA12 and ER 701-0, 6ES5 701-0LA11, Siemens specifies the 6ES5 981-0GB11 mounting kit. If the cabinet contains both rack sizes, use the nameplate of the rack being serviced to select the kit.
Cabinet mounting and cable routing
The brackets attach to the cabinet uprights or mounting surface below the rack. The duct hooks onto the brackets and can also be used on its own. Figure 3-16 in the manual shows how to access the fan subassembly with the duct fitted.
When routing S5 cables and connectors, leave room to service the front connectors of modules such as the 6ES5 431-7LA11 digital input and 6ES5 441-7LA11 digital output. If the cabinet has an expansion rack, also check the route of the IM 305 or IM 306 interconnection cable.
For an S5-115U cabinet fitted with a CPU 943 or CPU 944, identify the installed power supply and its load when checking cooling requirements. Siemens specifies a fan subassembly when the PS 951 6ES5 951-7LD21 or PS 951 6ES5 951-7ND41 supplies more than 7 A. The manual also calls for forced cooling when certain high-consumption modules are installed.
What to check on a used kit
Confirm the 0GA11 suffix and check for two brackets and the duct. Look for extra holes drilled into the brackets. To offer a kit for sale, send photos of the label and parts to otomasyonavm@gmail.com.
Editor’s note
Measure across the outer edges of the module rack. The long rack is in the 483 mm class.
Lay out both brackets and the duct before buying a used kit. Check for bent fan guides and broken duct hooks.
With power isolated and the duct removed, slide the fan assembly into both guides together. Check that both latches engage.
If the fan binds on one side, stop and check that the brackets are parallel and the mounting holes line up.
Refit the duct and check that the front connectors remain removable and the cable bundle clears the fan intake.
PDFs and Siemens references
- Siemens S5-115U manual (EN), mounting on p. 3-16 and fan compatibility on pp. 15-67–15-68
- Siemens ST 50 catalogue (DE), long and short rack variants on p. 3/77