6ES5 700-1LA11

Siemens 6ES5 700-1LA11 S5-115U CR 700-1 central rack

The 6ES5 700-1LA11 is a CR 700-1 central rack for Siemens SIMATIC S5-115U. The full-code parts entry specifies seven free module positions. The 1987 S5-115U system record lists this rack alongside the CPU 942 (942-7UA11) and S5 power supplies. The PS 951 7LB13 is one supply listed in that table.

Slot layout and installation

The Siemens CR 700-1 family drawing shows PS, CPU, positions 0–6 and IM. Placement of digital inputs, digital outputs and analog modules depends on the card type. The 430-7LA11 digital input module is one example in the 1987 component table. In the family drawing, analog modules in positions 4–6 require IM 306. Compare the drawing with the installed layout before applying it to a 1LA11 rack.

The family manual shows IM 305 and IM 306 for central expansion. Record the direction of the S5 interconnecting cable and the location of the termination plug before removal. The ER 701-1 1LA11 is a separate expansion rack.

The family drawing shows position 0 for the CP 530-7. Some communications processors and function modules require an adapter in that position. Read the label on the installed casing. Check a code such as 491-0LA12 against the module and rack documentation before selecting an adapter.

Choosing a used rack

The full-code parts entry gives dimensions of 483 × 303 × 47 mm (W × H × D) and a weight of 5 kg. A parts listing identifies the 700-1LA12 as the successor. Compare the backplane and slot layout before replacing the rack. The CR 700-2 2LA12 and ER 701-1 1LA12 have their own slot tables. Before removal, record the condition of the mounting accessories with cable duct and other connecting hardware.

Editor’s note
1. Isolate cabinet and field supplies and verify that power is off. Photograph card labels, slot numbers and the IM connection before removal.
2. For a used rack, ask for close-ups of the 700-1LA11 label and the PS, CPU, 0 and IM positions. Inspect the backplane pins and card guides.
3. If a single card is unreachable, inspect its front connector, backplane contact and slot before ordering a rack.
4. If the fault affects analog modules or the expansion unit, compare the IM order number, cable and termination with the cabinet schematic.
5. Before fitting the successor 1LA12, check each card and slot against the Siemens drawing. Pay particular attention to the slot 0 adapter and the IM position.
6. During controlled recommissioning, verify CPU status, local I/O and the expansion link separately.

Manual and reference documents

Siemens S5-115U manual, CR 700-1 family drawing p. 3-4 (EN) · 1987 S5-115U component table, full 1LA11 order number (ES)

SIMATIC S5 PDF archive

Related topics

About Siemens S5 PLC · SIMATIC S5 modules · S5 interface modules

Used Siemens equipment · S5 racks · SIMATIC S5 · Siemens S5 PLC · Used Siemens main page