Siemens 6ES5 984-1UB11 – PG 605U Adapter with Printer Connection
Siemens 6ES5 984-1UB11 is a 984 adapter with a printer connection for the PG 605U programmer. The Siemens manual specifies this order number for the S5-101U in the S5 family. Use the complete product code when identifying programming and printer accessories for a SIMATIC S5 installation.
Record the programmer order number separately, including versions such as 6ES5 605-0UA11 and 6ES5 605-0UA12. Select an adapter by checking the programmer version, controller label and intended printer connection together.
S5-101U Compatibility and Order Number
Page 2-1 of the PG 605U manual identifies 6ES5 984-1UB11 as being only for S5-101U. When reviewing S5 CPU models, also record the complete controller order number and revision, for example 6ES5 101-8UA11 or 6ES5 101-8UA13. Claims of shared S5-100U compatibility require separate manufacturer documentation.
Nearby references such as 6ES5 984-1UA11, 6ES5 984-0DA11 and 6ES5 984-2UA11 should be compared individually when sourcing a replacement. Membership of the 984 order-number group alone does not establish an identical connection function or supported device range.
Connection and Physical Inspection
When checking the adapter against existing S5 cables and connectors, inspect the contacts, housing, locking parts and signs of cable strain. As with S5 interface modules and S5 communication modules, match the connection documentation to the complete product code.
Verify the pin assignment, supply and signal connections before preparing a test cable. A voltage rating from a neighboring adapter or a visually matching connector is insufficient to establish the correct wiring. Follow the relevant manufacturer instructions when connecting or disconnecting the equipment.
Checking Programming and Printer Output
During PLC programming, first check that the existing program can be read and that the connection remains stable, then test output using a suitable printer. Information about PLC programming methods and programming software selection should be considered alongside the operating method supported by the programmer and controller.
Before transferring a program, record the status of existing backups and any S5 memory cards. During PLC debugging, testing the controller connection and printer path separately helps locate a fault. The Siemens S5 PLC overview provides further background on the legacy system.
Editor’s Note
Start by reading the 1UB11 suffix directly from the label. Ask for clear photographs of both the label and connectors before selecting a used replacement.
A clean connector shell can conceal bent or recessed contacts. If a connector resists insertion, check the mating parts and locking mechanism before applying force.
A working programmer-to-controller connection does not establish that the printer path is healthy. Where possible, use a known-good compatible printer and cable to obtain a readable test print.
Secure an up-to-date program backup before attempting write or erase operations. Preserve the existing program before investigating a connection problem.
Check the adapter, cable, programmer and controller in a clear sequence. Changing one item at a time makes intermittent faults easier to isolate and helps avoid unnecessary replacement costs.
Documentation and PDF Archive
Browse further S5 documentation in our S5-115 PDF archive. The adapter identification on this page is based on page 2-1 of the manufacturer’s PG 605U manual linked below.
Related Topics and Nearby References
6ES5 605-0UA11 · 6ES5 605-0UA12 · 6ES5 984-1UA11 · 6ES5 984-0DA11 · 6ES5 984-2UA11. These links support model comparison; they do not constitute approval as direct substitutes.
Siemens S5 Navigation
Used Siemens products · Siemens S5 main page · S5 CPU models · S5 expansion accessories · S5 function modules · Cables and connectors
External References
Siemens PG 605U Programmer Manual – EWA 4NEB 810 1056-02d. Section 2.1, printed page 2-1 / PDF page 13: order number 6ES5 984-1UB11 and S5-101U application.