Siemens 6ES5 921-3WB11 is a CPU 921 central processing module for the SIMATIC S5-130W Version B. It provides two user EPROM slots, internal user RAM, 128 timers and 64 counters. This Siemens automation module executes the Siemens S5 PLC program and manages data exchange with SIMATIC S5 peripheral modules.

Typical duties include machine sequencing, interlocks, timing and counting. Field signals are processed through digital input modules, digital output modules and analog modules. The CPU is a processing board; sensor compatibility, field voltage and output-current ratings depend on the relevant I/O module.

Memory arrangement and two EPROM slots

The manufacturer's table specifies 2 × 1024 instructions for the operating system and approximately 2.9 × 1024 instructions of user RAM. These figures are expressed in instructions, not KB. Assess operating-system storage and user-program memory separately. Select S5 memory modules against the CPU revision, memory type and existing program layout.

The CPU has two EPROM slots for the user program. The manual identifies 373 EPROM modules and 371 modules with a suitable cover. 6ES5 373-0AA21 and 6ES5 373-0AA41 are memory examples listed in the spare-parts table. An installed module or a readable label does not establish that its contents suit the machine.

The upper memory module starts at a fixed address of 4 × 1024 bytes; the lower module is automatically assigned the following address. Additional user RAM on 340/350 memory boards must end at 48 × 1024 bytes. This end-address requirement must not be interpreted as 48 KB of onboard CPU RAM.

Address resources, timers and execution time

The CPU address resources cover 512 inputs and 512 outputs, equivalent to 64 bytes in each direction. Flag storage is divided into 1024 retentive bits and 1024 non-retentive bits. The retentive area is M 0.0–M 127.7; the non-retentive area is M 128.0–M 255.7. Retention during a power interruption also depends on a functioning system backup-battery arrangement.

For the 128 timers, the manual specifies time bases of 10.24 ms, 102.4 ms, 1.024 s and 10.24 s, with a time value of 0–999. The 64 internal counters also have a range of 0–999. These are software resources rather than dedicated physical counter inputs on the CPU.

Binary-instruction execution time is approximately 3.5 µs. Scan-time monitoring is fixed at 360 ms and cannot be adjusted. Instruction time and complete program scan time are different quantities; assess lengthy blocks and peripheral waiting conditions together during fault finding.

Supply, programming and installation

The CPU module requires 5 V DC ±5%; current consumption is typically 3.5 A and 6 A maximum. The board is rated IP00, weighs approximately 0.68 kg and requires 40.64 mm of mounting width. Keep the central unit's 24 V supply specification separate from the CPU board's 5 V supply.

Programming access uses a suitable S5 interface board. For PG 511 options such as 6ES5 511-5AA12 and 6ES5 511-5AA14, verify the exact interface revision separately. The manufacturer manual describes PG 670 and PG 675 access; match the S5 cable and connector arrangement to the programmer and interface.

The bus drivers are specified to drive a maximum of 30 peripheral modules. In an actual installation, review the S5 rack and chassis, module power consumption, expansion connections and cooling conditions together. This limit does not establish unrestricted compatibility between every S5 module and every slot.

Comparison with nearby order numbers

6ES5 921-3WB13, 6ES5 921-3WB14 and 6ES5 921-3WB15 are different order codes; a later number alone does not establish replacement compatibility. 6ES5 921-3WA13 and 6ES5 921-1AA21 are also separate 921 models. Compare the complete order code, hardware revision, system software and memory arrangement before selection.

Editor's Note

Start with the complete CPU label and the modules fitted in both memory slots. Record the 3WB11 suffix together with the memory order numbers.

Before removing a working CPU, back up the program and data blocks. RAM contents, user EPROM and operating-system storage serve different purposes; establish what each backup actually preserves.

If EPROM modules must be removed, mark their upper and lower positions first. Their location matters to the address layout, so compare the existing arrangement with the documentation before moving them.

If faults appear as the equipment warms up, inspect the supply and fans too. With a typical CPU consumption of 3.5 A, a power-supply reading taken without load is only part of the assessment.

For a scan-time fault, examine the program, waiting conditions and diagnostic information against the fixed 360 ms limit. The Siemens S5 maintenance information provides background; assess a used CPU through programmer access and controlled functional testing in a suitable system.

OtomasyonAVM resources

6ES5 921-3WB11 main page · Used Siemens S5 models · Siemens S5 technical information

Related topics

921-3WB13 · 921-3WB14 · 921-3WB15 · 921-3WA13

These links support comparison and do not establish direct interchangeability or upgrade approval.

Navigation

Siemens · Siemens S5 · SIMATIC S5 · Memory modules · Interface boards · Racks and chassis

External references

Siemens S5-130W Version B Operating Instructions – GWE 548/002 J – German PDF