6ES5 902-3SA12

Siemens 6ES5 902-3SA12 – S5-110S CPU 902 Central Processing Module

Siemens 6ES5 902-3SA12 is a CPU 902 central processing module for the SIMATIC S5-110S/B. It provides 512 instructions of internal user RAM, one user EPROM slot, 128 timers and 128 counters. This Siemens automation module executes the Siemens S5 PLC program and manages data exchange with SIMATIC S5 peripheral modules.

Typical duties include machine sequencing, interlocks, timing and counting. Field signals are processed through digital input modules, digital output modules and analog modules. Assess the CPU's 5 V system supply separately from sensor, output-load and central-housing supplies.

Memory arrangement and EPROM selection

The manufacturer's table specifies 1 K instructions for the operating system and ½ K, or 512 instructions, of internal user RAM. Instruction counts and KB capacities are different units. When examining S5 memory modules and used memory modules, check program contents, module function and the complete order code together.

The CPU's single user EPROM slot accepts the listed options 6ES5 911-0AA31: 2 K instructions, 6ES5 911-0AA42: 4 K instructions and 6ES5 911-0AA52: 8 K instructions. Suitable 340 RAM or 350 RAM/EPROM memory boards provide additional user-program and data storage.

When EPROM submodules on a 350 board are used, an 8 K-instruction EPROM submodule must remain fitted on the CPU even if it contains no user program. This is a manufacturer installation requirement. Keep the CPU's 911 module distinct from the EPROM submodules and address arrangement on the 350 board.

Timers, counters and addressing

The CPU provides 128 timers and 128 internal counters. Timer bases are 0.01 s, 0.1 s, 1 s and 10 s, with a factor of 0–999. The German manufacturer manual confirms a counter range of 0–999. These are software resources rather than corresponding physical inputs on the CPU.

Flag storage consists of 1024 retentive bits and 1024 non-retentive bits. The retentive area is M 0.0–M 127.7; the non-retentive area is M 128.0–M 255.7. Retention of RAM contents and retentive areas during a power interruption depends on the system's backup-battery arrangement.

The basic 110 bus and additional compact modules use different addressing arrangements. The manual assigns additional compact I/O modules to byte addresses 64–127, or 40H–7FH. Their process-image refresh and output transfer must be handled by the user program; reference only peripheral addresses that are physically connected.

Supply, execution time and housing identification

The CPU uses a 5 V DC system supply, with 1.6 A typical and 2.6 A maximum current consumption. Binary-instruction execution takes less than 8 µs. The operating section specifies a maximum user-program cycle time of 270 ms. Assess the actual scan against program structure and peripheral activity.

Housing order codes such as 6ES5 932-3SA12 and 6ES5 932-3SA11 identify different components from the 6ES5 902-3SA12 CPU. A housing's mains voltage must not be assigned to the CPU board. Siemens' spare-parts list gives an approximate CPU weight of 1 kg.

External I/O arrangements include parts such as the 6ES5 710-0SA11 eight-slot rack and 6ES5 710-0SA41 sixteen-slot rack. Review the S5 rack and chassis, connection cables and installed-module addresses together.

Programming and diagnostics

Programming access uses a separate S5 interface board. The manual lists 6ES5 511-5AA12 and PG 670/PG 675 arrangements. Check software and hardware suitability separately when considering other revisions such as 6ES5 511-5AA14. Select S5 cables and connectors against the programmer and interface.

512C communication boards such as 6ES5 512-5BC12 perform a different function from the programming interface. The manufacturer warns against using the PG 670–511 cable for a 512C connection. 6ES5 902-3SA11 is also a different order code; the CPU 902 name alone does not establish replacement compatibility.

The green Run indicator relates to central-processor operation, while the orange Program running indicator relates to cyclic user-program execution. The yellow Output Inhibit/BASP indicator shows that outputs are inhibited. The service OFF/ON switch has a different function from the normal Run/Stop control.

Editor's Note

Start with clear CPU and EPROM labels. Distinguish the 902 processor from the 932 housing so that the required spare is identified correctly.

If the program can be read from a working system, back it up before replacement. Battery failure can erase RAM; successful powered operation does not prove retention after power is removed.

With a 350 memory board, preserve the CPU's required 8 K EPROM arrangement. A program residing in external memory does not remove that installation requirement.

A green RUN indicator is only part of the assessment. Check the orange program indicator, BASP state and programmer diagnostics together, and avoid experimenting with service controls.

Remove and insert the CPU and memory module with power disconnected, then perform program comparison and controlled functional testing in a suitable system. The Siemens S5 maintenance information provides background; assess a used unit against its own test record.

OtomasyonAVM resources

6ES5 902-3SA12 main page · Used Siemens S5 models · Siemens S5 technical information

Related topics

902-3SA11 CPU · 932-3SA12 housing and power supply · 710-0SA11 rack · 511-5AA12 programmer interface

These links identify different system components; the parts are not presented as interchangeable.

Navigation

Siemens · Siemens S5 · SIMATIC S5 · Memory modules · Interface boards · Racks and chassis

External references

Siemens S5-110S/B Operating Instructions – GWA 4NEB 8072121-02 – English PDF
Siemens S5-110S Operating Instructions – GWA 4NEB 8072121-01, archive copy – German PDF