6ES5 491-0LD11
Siemens 6ES5 491-0LD11 – S5-115U/H/F Adapter Casing for Four Compact Modules
Siemens 6ES5 491-0LD11 is the double-width adapter casing used to install ES 902 compact modules in S5-115U/H/F systems. Siemens Catalog ST 50 specifies accommodation for up to four compact modules, dimensions of 86 × 303 × 187 mm and an approximate weight of 0.8 kg. It is a mechanical mounting accessory within the SIMATIC S5 and S5 supplementary equipment ranges.
The four compact-module positions should not be confused with four standard S5-115U module positions. The arrangement depends on card width and the selected rack. Within a SIMATIC S5 system, the casing supports the cards mechanically; channel count, signal type and communication functions belong to the installed modules.
Width differences between LB11, LD11 and LC11
The ST 50 selection table lists 6ES5 491-0LB11 as single-width for up to two compact modules, LD11 as double-width for up to four and 6ES5 491-0LC11 as triple-width for up to six. Select by the exact casing specification rather than appearance or the 491 family name alone.
Keep other references, including 6ES5 491-0LA11 and 6ES5 491-0LA12, separate when checking labels. Do not assume that different casing codes provide the same width or installation arrangement. Compare the existing card assembly and its mounting parts together.
Rack selection and card arrangement
The catalog lists CR 700-0LB, CR 700-2, CR 700-3 and ER 701-3 rack families for LD11. When choosing an S5 rack, verify the exact version and permitted installation position of CR 700-0LB, CR 700-2 or CR 700-3. Electrical operating requirements must also be checked for an ER 701-3 expansion arrangement.
Available space does not establish that a card can operate with the selected rack and CPU. Assess card width, connection position, neighbouring modules and clearance together. Align the card with its guides rather than forcing it onto the connector, and check the fixing arrangement.
CP 580 and CP 581 assemblies
The Siemens CP 581 ordering table identifies 6ES5 491-0LD11 as an adapter casing for four slots. When preparing a CP 580 or CP 581 basic-board assembly, use the complete assembly width and its installation drawing. The casing alone does not determine processor or software compatibility.
With storage hardware such as CP 581 3LA11 or CP 581 4LA11, include more than the basic board when assessing space. Check the complete assembly, screws and spacers. The arrangement of the full S5 communication equipment determines how much casing space is needed.
Fixings, covers and cooling
The S5-115U installation manual describes securing an adapter casing to the rack, sliding the card along its guides and locking it in place. Cover any remaining front opening with a suitable blanking plate. Connecting cables should not place excessive strain on the assembly, and connector access must remain available when interface equipment is fitted.
The ST 50 ordering description includes one protective cover; confirm the actual cover and mounting parts supplied with a used unit. Determine fan requirements from the installed modules’ instructions. Assess S5 power supply capacity and airflow separately from the casing width.
Editor’s Note
Start by checking the side panels and card guides for distortion. Impact damage can steer a board incorrectly towards its connector. With used Siemens equipment, smooth card insertion matters as much as a clean exterior.
Ask the seller to show the cover, locking parts and fixing screws individually. Missing hardware can delay installation. Establish whether any cards visible in the photographs are included in the offer.
Do not read “four modules” as a promise that any four cards will fit. Double-width boards and combined assemblies can require additional space. Compare the casing with the actual assembly you intend to install.
If a card resists insertion, inspect alignment and guides first; do not pull it into place with the screws. During S5 maintenance, forcing a mechanical fit can damage the backplane connector. Remove power before inserting or removing equipment.
For faults that appear after warm-up, check the fan, airflow path and cable arrangement as well as the cards. An assembly that fits mechanically still needs the cooling required by its installed hardware.
OtomasyonAVM resources and PDFs
Start with S5 supplementary equipment, S5 racks and the SIMATIC S5 overview. The OtomasyonAVM S5 PDF archive provides a starting point for documents. Siemens ST 50, 1998, page 3/98 gives the width, capacity and dimensions for the exact model. The CP 581 manual lists LD11 as a four-slot adapter casing on page 5-4. These documents are in English.
Related topics
+ 491-0LB11 · 491-0LC11 · 491-0LA12 · CR 700-3
Browse SIMATIC S5
+ S5 supplementary equipment · S5 racks · SIMATIC S5 · Used Siemens overview