6ES5 241-1AD12

Siemens 6ES5 241-1AD12 IP 241 BCD / binary encoder matching card

The 6ES5 241-1AD12 is a single-channel encoder matching card for the IP 241 position decoder in SIMATIC S5 systems. It takes absolute position data in parallel BCD or binary code from the encoder and passes it to the 6ES5 241-1AA12 basic module. In a two-channel installation, select each matching card for its own encoder.

Code, signal and wiring

Verify the encoder output type against the label and wiring drawing. The 1AD12 uses parallel inputs, whereas the 1AB11 reads incremental pulses, the 1AC11 reads Excess-3 Gray code and the 1AF12 uses a synchronous serial interface. Siemens specifies up to 17 bits for binary input converted to BCD and 20 bits for binary processing. The mode depends on switch S1 and the format used for setpoints.

The encoder connects through the 50-pin D-sub for its channel on the basic module. When checking the cable, compare bit order and M potential with the machine drawing. Trace the coded lines separately from the PLC’s digital input and digital output circuits. Check encoder signal level and encoder supply voltage separately. Siemens lists card consumption of 0.4 A at 5 V and 0.35 A at 24 V and a maximum input frequency of 50 kHz. Include the basic module’s consumption in the power supply budget.

Basic module and installation

The S5-115U system manual specifies a fan and adapter casing for the complete IP 241 assembly. Check the applicable rack slot diagram, for example the drawing for the CR 700-2. The system manual specifies the 6ES5 491-0LB11 adapter casing for marked slots on the CR 700-2LB. Compare the input resistor networks and S1 setting with the original card. Siemens lists 6ES5 271-1AD11 as the BCD/binary configuration set.

Use the 1AD12 suffix when sourcing a spare. The IP 241 MIR is a separate variant. The IP 246 A is a different positioning module for axes with DC drives. Match the basic module, encoder code and channel wiring together when selecting a replacement.

Editor’s note

+ When buying a used card, request a photo showing the label, S1 switch and resistor networks. Check whether the fitted components match your encoder output.

+ After safely isolating the equipment, record the channel and S1 position. Back up the STEP 5 project and IP 241 parameter data blocks.

+ For BCD operation, watch consecutive raw readings such as 8, 9 and 10 during a controlled test. If the fault appears at the 9-to-10 transition, check bit order and the lines carrying the tens digit.

+ If the position is frozen or invalid at startup, check whether the encoder powers up after the card. Siemens notes that the reading may update correctly once the least significant bit A0 changes.

+ If readings are correct at low speed but intermittently wrong at higher speeds, inspect the connector, shield and bit lines first. Then compare the card’s input configuration and C21 delay with the documented setup.

+ After fitting the spare, follow the site procedure and compare the raw encoder reading and PLC-scaled value at two known positions. This helps distinguish wiring errors from scaling errors in the program.

For a used card, ask which code and signal level were tested. To sell a module, email the full part number, quantity, operating condition, label photo and asking price to otomasyonavm@gmail.com.

PDFs and Siemens references

+ IP 241 manual, BCD/binary matching card, Chapter 5 (EN)

+ IP 241 manual, full part number and specifications, p. 8-1 (EN)

+ IP 241 manual, Absolute 2 encoder matching card (DE)

+ S5-115U system manual, installation requirements, Table 15-1 (EN)

+ Siemens S5 PDF archive

Related topics

+ About Siemens S5 PLCs

+ What is an absolute encoder?

+ Encoder output signal types

Second-hand Siemens

+ S5 positioning modules

+ S5 CPU range

+ Siemens S5

+ Second-hand Siemens main page