6ES5 926-5AA12
Siemens 6ES5 926-5AA12 – S5-150A second central module, 2 KB system RAM
Siemens 6ES5 926-5AA12 is the 926-5 central module for the S5-150A in the SIMATIC S5 family. It is the second module in a three-module central processing assembly and contains 2 KB system RAM. Within this Siemens S5 architecture, it must be assessed as part of the complete central assembly.
The central assembly comprises 925-5, 926-5 and 927-5 modules. The Siemens ST 53 ordering table lists 6ES5 925-5AA12, 6ES5 926-5AA12 and 6ES5 927-5BA12 for ZG 150A. Review the hardware and operating-system versions of the installed assembly before replacement.
System RAM versus user program memory
The 2 KB system RAM contains system data, storage for 128 counters, 128 timers and 2048 flags, and the input/output process images. User code resides on separate RAM/EPROM memory modules. Record the complete S5 memory module codes and address settings separately from the central modules.
The system memory map defines a 48 KB user area. This does not mean that the 926 module contains 48 KB internal program RAM. When backing up the STEP 5 application, document the fitted memory arrangement too. Confirm that the programming software and connection hardware support this early S5-150A architecture.
Programmer connection and communications
PG access uses a separate 511-5 programmer interface module. Select the S5 programming cable by matching the programmer, adapter and exact interface module code. Do not plan the connection as though the 926-5AA12 had an independent modern PG port.
The system manual shows a 512 interface for communication with computers and other controllers. Assess S5 communications modules as separate hardware; their protocols and connections should not be attributed to the 926 module itself.
Process image and address checks
The input process image holds 128 bytes / 1024 bits, as does the output process image. These are not physical channels on the 926 module. Compare digital input and digital output module addresses with the existing application and actual hardware arrangement.
Supply and memory jumpers
The specified supply for the central module assembly is 5 V DC ±5%. Mains or 24 V input ratings belong to the S5 power supply. Inspect rack and bus connections for poor contact, oxidation and supply performance under load.
Br.2 relates to enabling or masking user memory; Br.3 performs the corresponding function for system-data memory. Br.4/Br.5 concern the NMOS/CMOS RAM supply selection. Match the hardware revision and fitted RAM type to the Siemens table before changing any jumper.
Operating controls, diagnostics and used-unit checks
The Betrieb/Stop selector and Wiederanlauf pushbutton are on the 926-5AA12. The manual distinguishes a new start from resuming interrupted execution. During PLC troubleshooting, inspect the STOP cause and U-Stack before choosing a restart mode.
Assess a used PLC CPU module with the appropriate central assembly, memory and programmer interface. For used Siemens equipment, clarify which modules, covers and memories are included, using photographs of their labels.
Do not select a different construction or system code such as 6ES5 926-3KA12 merely because it shares the 926 designation. Base model comparisons on complete order numbers. If considering Derell PLC options for modernization, redesign the program, I/O mapping and communications for the new project.
Editor's Note
First establish the complete three-module central assembly. Record the 925 and 927 module codes, system memory and operating-system version before buying a replacement 926 module.
Keep 2 KB system RAM and separate user program memory distinct. Identify where the application resides, which memory module is fitted and whether the backup can be restored.
Photograph jumper positions before removal. Br.2–Br.5 affect memory functions; do not copy another board’s arrangement by appearance. Match the RAM type and hardware revision.
If PG access fails, check the 511-5 interface, cable, programmer and adapter together before condemning the 926 module. Preserve diagnostics before considering a memory reset.
Check the battery, 5 V supply and actual I/O operation together. Have a backup before disconnecting power, remove modules with power off and establish the machine state before selecting a restart mode.
OtomasyonAVM resources and PDFs
6ES5 926-5AA12 main page · Used Siemens S5 models · Siemens S5 PDF archive
References: Siemens S5-150A Zentralgerät, C79000-B8500-C227-2; System 8 commissioning documentation, I/2, printed 5-14; and ST 53 / 1985, printed 9/9. These documents are in German. The system RAM and user-memory distinction follows the S5-150A memory map.
Related topics
6ES5 925-5AA12 · 6ES5 927-5BA12 · 6ES5 926-3KA12 · Derell PLC options
Navigation
SIMATIC S5 · Siemens S5 models · Used Siemens · S5 memory modules · S5 interface modules
Siemens and external references
Siemens S5-150A operating instructions – 926-5AA12 controls, German archive copy
System RAM and user memory map, printed 19 · Siemens System 8 – exact 926-5AA12 jumper table, printed 5-14
Siemens ST 53 / 1985 – ZG 150A central module order codes, printed 9/9