6ES5 924-3SA11
Siemens 6ES5 924-3SA11 – S5-150S / S5-150U Central Processor Board 924
Siemens 6ES5 924-3SA11 is board 924 in the SIMATIC S5-150S and S5-150U central processor assembly. The manufacturer’s spare-parts list identifies it as central board 1. The Siemens catalog specifies 5.3 A current consumption at 5 V and an approximate weight of 0.43 kg for board 924. Use these details alongside the complete order number when maintaining Siemens S5 and SIMATIC S5 equipment.
The board forms the central processor assembly together with 6ES5 925-3SA11, 6ES5 926-3SA11 and 6ES5 927-3SA11. Record all four board references, revisions and connections before selecting a spare. 6ES5 924-3SA12 has a different suffix; verify replacement suitability against the relevant manufacturer documentation.
Power Supply and Rack Position
Board 924 uses the central controller’s 5 V system supply. The catalog’s 5.3 A figure describes board consumption. When assessing the S5 power supply, include the loads of the other installed modules and inspect the board’s rear contacts and supply connections.
The S5-150S layout shows 924-3SA11 in position 51. The S5-150U manual places boards 924/925/926/927 in positions 35/43/51/59, respectively. Check the installed S5 rack and chassis against its own drawing. Also record bus connection components such as 6ES5 756-0AA11 where fitted and the positions of S5 memory boards.
Jumper Arrangement and Board Replacement
The manufacturer’s drawing of 924-3SA11 shows a Br. 1 jumper. Photograph its position, both sides of the board and the revision label before removal. Compare the jumper arrangement with documentation for the complete reference and with the installed application. Similar-looking S5 function modules may use jumpers for different purposes.
Programmer Connection and Fault Checks
The S5-150S manual lists 6ES5 511-5AA12 for the PG connection. Assess other versions such as 6ES5 511-5AA14 separately. Check the installed S5 cables and connectors, S5 interface modules and S5 communication modules against the hardware records when establishing programmer access.
Back up the STEP 5 program and system data before PLC programming or board replacement. During debugging, assess supply stability, rear connector contact, memory configuration and the other central boards together. Consult the Siemens S5 PLC overview for further background.
Editor’s Note
Read the complete 924-3SA11 label before selecting a spare. Record the references of boards 925, 926 and 927 as well so the complete assembly is identified.
Interpret the catalog’s 5 V / 5.3 A figures carefully. Investigate voltage drop or hot connector contacts before replacing a board.
Check the actual 150S or 150U rack layout. Mark the board position and photograph the housing label and arrangement before dismantling.
Photograph Br. 1 before moving it. Use the documentation for board 924 rather than copying a neighboring board’s jumper setting.
Preserve the program backup and assess the board in a suitable central assembly. Record connector condition, memory configuration and the observed fault to avoid unnecessary replacement.
Documentation and PDF Archive
Browse further S5 documents in our S5-115 PDF archive. Use the manufacturer references below for this board’s 150S/150U installation and ordering details.
Related Topics and Nearby References
6ES5 925-3SA11 · 6ES5 926-3SA11 · 6ES5 927-3SA11 · 6ES5 924-3SA12. These links support comparison of assembly components and nearby versions; they do not establish direct interchangeability.
Siemens S5 Navigation
Used Siemens products · Siemens S5 main page · S5 function modules · Racks and chassis · Memory boards · Interface modules
External References
Siemens Zentralgerät 150 S – C79000-B8500-C246-3, German: §1.2.1 layout; §3.2.1 jumper drawing; §4.4 spare parts.
Siemens S5-150U Handbuch, German: PDF 15 rack positions; PDF 37 jumper drawings; PDF 47 spare-parts list.
Siemens ST 53, 1985 catalog – manufacturer document copy: technical table 8/2 and May 1985 order references.