6ES5 391-5AA13
Siemens 6ES5 391-5AA13 – Operator Panel for the 390 Timer/Counter Module
Siemens 6ES5 391-5AA13 is a 391 operator panel with housing used with the 390 timer/counter module in the Siemens S5 PLC family. In the SIMATIC S5 system, it provides entry and display of timing and counting values, together with numerical display of programmed fault messages.
Siemens ST 53 lists this complete order number as a housed operator panel for module 390. Used alongside S5 special modules, its role is to give the operator access to the 390 board’s timing and counting functions. Assess the panel, connecting cable and 390 board together when selecting a spare.
Numeric keypad and value displays
Timer and counter addresses and their associated values are entered through a numeric keypad and read from numeric displays. The catalog identifies functions for displaying actual values, displaying setpoints, entering setpoints and advancing to the next address. When comparing Siemens operator panels or other HMI and panel types, consider this specific role of the 391.
The front panel has running-status LEDs for timers at addresses 0–15. Each LED remains lit while the corresponding timer is running. For timing and counting applications, read the selected address, displayed value and timer/counter mode together. Depending on the application program, the 390/391 arrangement can numerically display 32 programmable fault messages.
Checking addresses and setpoints
The selected panel address identifies a timer or counter in the connected 390 module. Keep this distinct from the address of a field input or output. Check actual values and setpoints separately. Recording the addresses in use, selected mode and existing setpoints before maintenance makes incorrect parameter changes easier to trace.
Connecting cable and system matching
The Siemens catalog describes connection to the 390-5 module using a 1.5 m cable. Check separately whether that cable is included with a used assembly. Inspect pins, cable entry and contacts when reviewing S5 cables and connectors; at the S5 rack, record the connected 390 board’s complete order number and connection point.
Distinction from related panels
6ES5 391-5AA12 is a nearby order number; similar numbering alone does not establish identical functions, housing or cable assemblies. 6ES5 393-0UA11 is another operator panel. A panel being intended for S5 does not establish that it connects directly to module 390.
Other S5 operator devices such as 6ES5 395-0UA11 and 6ES5 396-0UA11 must also be assessed against their own system connections. Before considering a change, identify the values to be displayed, parameters the operator must modify and existing connection arrangement.
Maintenance and functional checks
During PLC troubleshooting, compare the panel display with the 390 board and application-program state. Following the maintenance approach in About Siemens S5 PLC, record the existing condition first, then inspect the keypad, display segments, running-status LEDs and cable connection separately.
When assessing Siemens automation spares or S5 expansion modules, request the complete 6ES5 391-5AA13 nameplate, revision, housing condition and connecting cable together. Verify supply connections and connector pin assignments using the device markings and applicable connection documentation.
For a used HMI or operator panel, check every key and display digit. Preserve separate backups of the CPU program and any system S5 memory cards; replacing the panel does not itself back up the machine program or its recorded settings.
Editor's Note
Assess the panel together with the 390 board’s order number and connecting cable. Requesting only an OP391 can result in an incomplete assembly. Obtain clear photographs of the nameplate, housing and cable before selecting a spare.
Readable numbers do not complete the check. Inspect every display digit for missing segments, check every key and look for repeated entries from a single press. A poorly displayed digit can also lead to a setpoint being misunderstood.
Record the address, mode and original value before changing a setpoint. Distinguish actual values from setpoints. Perform functional checks under suitable machine-maintenance conditions where the effect of an entry can be observed.
If the display remains blank, inspect the cable, connector pins and connected 390 board as well as the panel. A broken conductor or loose contact in an older cable can make a serviceable panel appear faulty.
Do not assume a displayed fault number has the same meaning across all S5 installations. Its interpretation may depend on the machine application program. Preserve any original electrical documentation and fault list with the panel; a short machine-specific list can be particularly valuable during maintenance.
OtomasyonAVM resources and PDF files
See 6ES5 390-5AA22 for the associated board and the Siemens S5 PDF files archive for shared documentation. Review the 390 board and 391 panel documentation together when assessing the connection.