Siemens 6ES7 141-3BH00-0XA0 — ET 200eco BM141, 16-Channel Digital Input Module
6ES7 141-3BH00-0XA0 is an ET 200eco BM141 basic module in the Siemens ET 200 distributed I/O family. It provides 16 digital inputs at 24 V DC through eight M12 sockets. Among ET 200 digital input modules, it collects sensor and switch signals directly on the machine. Its protection rating is IP65/IP67 when correctly installed and connected.
PROFIBUS-DP and connection block selection
The module communicates over PROFIBUS-DP at speeds up to 12 MBaud. When comparing ET 200 communication interfaces, start with the installed master and field wiring. Within the ET 200 system and product families, this device belongs to ET 200eco; do not assume project or wiring compatibility with ET 200eco PN.
Power and bus connections require a 6ES7194-3AA00-0BA0 M12–7/8″ or 6ES7194-3AA00-0AA0 ECOFAST connection block, ordered separately. When selecting ET 200 connection modules, match the connector arrangement to the installation. If reusing an existing block during replacement, inspect its mechanical condition as well.
How eight sockets provide 16 inputs
Across X1–X8, pin 4 carries channels 0–7 and pin 2 carries channels 8–15. X1 therefore carries channels 0 and 8; X8 carries channels 7 and 15. When selecting M12 field connectors and cables, check that both signal paths are available. A suitably wired Y connector or Y cable can connect two separate sensors to one socket.
Prepare a socket-to-channel-to-PLC-address list before installation. Connecting a sensor cable that uses only pin 4 does not also connect the second channel on that socket.
Sensor supply and signal duration
The sensor supply outputs have a combined limit of 1 A up to 55 °C. Include every sensor when calculating power distribution and supply loading. For example, 16 sensors drawing 80 mA each total 1.28 A and exceed the limit. Installing a larger 24 V industrial power supply does not increase the module's sensor supply capacity.
Input delay is typically 3 ms in both transition directions. When selecting industrial sensors for the application, assess output type and active signal duration as well as voltage. If the application must count fast pulses, review ET 200 counter modules against the required counting speed.
Five checks before selection
1. Exact code: Confirm 6ES7141-3BH00-0XA0 on the label. An eight-socket housing does not necessarily mean eight input channels.
2. Connection block: Match M12–7/8″ or ECOFAST to the installation. Confirm whether the block, caps and cables are included.
3. Sensor loading: Check continuous consumption and startup conditions. Calculate the load of all connected sensors, not just one socket.
4. Project and address: In the SIMATIC S7 hardware configuration, verify the device entry, PROFIBUS address and input mapping. Back up the project before replacement.
5. Field test: Operate each sensor separately and check that the correct PLC input changes. Include the second signal path and both Y-cable branches in the test.
Editor's Note
A cable splitting into two branches does not guarantee the required wiring. It must route two independent input signals to the correct pins. If one sensor works and the other is not detected, check continuity of the second signal path and the PLC address before concluding that the module is faulty.
PDF manuals and wiring diagrams: Visit the Siemens ET 200 manuals and PDF documents page. English manual A5E00158716-AD covers this model in section 8.5, pages 75–78; section 3.4 covers M12 and Y connections.
Related Topics
Digital Input Modules · Counter Modules · Connection Modules · Communication Interfaces
Otomasyon AVM
Siemens Main Menu ·
SIMATIC S7 ·
ET 200 Modules ·
ET 200 PDF Manuals ·
PLC and HMI