6ES7 131-0BL00-0XB0
6ES7 131-0BL00-0XB0
Series: Siemens SIMATIC DP / ET 200B
Category: ET 200B Digital Input Electronic Block – 32 DI, 24 V DC, 3 ms
Description
6ES7 131-0BL00-0XB0 is a 32-channel digital input electronic block for the Siemens SIMATIC ET 200B distributed I/O system. It acquires nominal 24 V DC field signals and transfers their status through the station’s PROFIBUS-DP communication.
Within the ET 200 family, this product serves block I/O applications collecting numerous inputs at one station. When selecting a digital input module, assess the electronic block, terminal base and existing project information together.
Device Function and Applications
The module acquires on/off information from pushbuttons, limit switches and electrically compatible proximity sensors. Machine position, part presence and auxiliary equipment status can then be processed by the connected PLC. Matching channel numbers to field labels makes fault investigation easier throughout the automation system.
This version has a specified 3 ms input delay. Assessing when a signal reaches the machine program also requires considering sensor response, communication updating and PLC cycle time. Observing the channel LED alone may be insufficient for short pulses.
Technical Specifications
Order number: 6ES7131-0BL00-0XB0
System: SIMATIC ET 200B
Product type: Digital input electronic block
Digital inputs: 32 DI
Rated input voltage: 24 V DC
Signal “1” input range: 13–30 V DC
Signal “0” input range: −30 to +5 V DC
Input current: Typically 4 mA at 24 V
Input delay: 3 ms
Communication: PROFIBUS-DP
Maximum supported communication rate: 12 Mbit/s
Channel status indication: Green LEDs
Station indicators: Green RUN, red BF
Degree of protection: IP20
Combined electronic block and terminal base dimensions: 235 × 130 × 60 mm
Combined electronic block and terminal base weight: Approximately 800 g
The dimensions and weight describe the combined EB electronic block and TB terminal base. If a listing offers only the electronic block, these figures should not be interpreted as the dimensions or weight of that individual delivered component.
Sensor Compatibility and Signal Levels
The sensor output must reach the defined input voltage regions for reliable state recognition. Investigate signals remaining between those regions because of voltage drop, loose terminals or incorrect common connections. Comparing measurements at the sensor and module terminal helps identify where the signal is lost.
Off-state current matters when using two-wire electronic sensors. The Siemens data sheet specifies a maximum permissible value of 1.5 mA. Check this characteristic alongside operating voltage when selecting a sensor. Include sensor connectors and cable joints when investigating intermittent signals.
Terminal Base and Connection Arrangement
The electronic block operates with an appropriate ET 200B terminal base carrying the field wiring. Siemens documentation lists options including TB2/DC – 6ES7193-0CB10-0XA0, TB2-4/DC – 6ES7193-0CB20-0XA0 and TB4/DC – 6ES7193-0CB30-0XA0. Select the terminal block according to the existing wiring and required terminal tiers.
The terminal base also matters for station addressing and the communication connection. When checking connection components, inspect more than the electronic module label. Confirm separately whether the electronic block, terminal base and other ET 200 accessories are included in the order.
Supply, Sensor Current and Fuse
The L5+ connection supplies the electronics and sensors. Siemens specifies an operating range of 18.5–30.2 V for the nominal 24 V DC supply. When investigating the power infrastructure, measure voltage under the operating conditions in which the problem occurs where practical.
The sensor supply current limit and fuse rating describe different requirements. Technical data specifies a maximum sensor load of 1 A, while the manual identifies an F1, 2.5 A fuse protecting the sensor supply in the terminal base. The fuse rating does not permit an increase in the continuous sensor load.
If several inputs disappear together, inspect the common supply, fuse, terminal contacts and supply distribution. Assess the M reference and protective grounding connections against the correct terminal diagram.
PROFIBUS-DP and Programming Information
The ET 200B station is configured as a PROFIBUS-DP slave. Its 32 inputs produce four bytes of input data; read the starting address from the master project. The configured device description or GSD file must match the installed electronic block.
The maximum supported rate does not establish the speed of the actual network. The master and network arrangement determine the operating rate; the manual specifies a maximum of 1.5 Mbit/s when using an IM 308-B. When assessing PROFIBUS communication, check the cable, connectors and termination together.
Compare the station address set at the terminal base with the project configuration. When reviewing broader ET 200 networking options, use this product’s PROFIBUS-DP connection as the basis for compatibility checks.
RUN, BF and Channel Indicators
The RUN indicator helps assess supply and operating status, while BF relates to bus communication. Channel LEDs indicate input states. If RUN remains off, check the supply and the terminal base’s STOP/RUN switch position.
For a BF indication, investigate the station address, master configuration, bus connection and line termination. If a channel LED changes but PLC data does not, check address mapping and communication. If the sensor operates but the LED does not change, trace the field signal through to the terminal.
Distinguishing 0BL00 from 0BL10
6ES7131-0BL00-0XB0 has a 3 ms input delay. The similarly numbered 6ES7131-0BL10-0XB0 is the 0.2 ms version. Consider this difference particularly when monitoring short pulses, and select replacement parts using the complete order number.
Maintenance and Commissioning Recommendations
Before replacement, record the terminal base, station address and project information. The Siemens manual requires setting the terminal base to STOP before inserting or removing the electronic block. Follow the documented installation and commissioning sequence.
Editor’s recommendation: Include the terminal base alongside the electronic block in fault investigation. Compare sensor output, channel LED and PLC input bit together. For shared input loss, start with supply and fuse checks; for station communication loss, start with addressing and the bus connection.
Related Topics
Explore SIMATIC S7 products and the Siemens S7 PLC category for related controllers and automation equipment.
+ Siemens ET 200 PLC user manuals (PDF documentation page)
+ Siemens ET 200B system manual covering 6ES7 131-0BL00-0XB0 (English PDF; section 7.3.2)
+ Siemens ET 200 general product catalogue (PDF file; consult the ET 200B manual for model-specific information)
++ Siemens Automation Main Page >
++ Siemens Automation Contact (for Otomasyon AVM)
Reminder: Availability, quantity and scope of delivery for Siemens 6ES7 131-0BL00-0XB0 and other SIMATIC PLC modules must be checked against the individual listing. Some devices are used products; consider their stated condition before purchasing. Products will not be restocked once sold out. This page provides general information; consult the manufacturer’s documentation for definitive specifications and application requirements.
Note: Manuals, commissioning explanations and troubleshooting suggestions on this page are non-binding and may be updated or improved. The Otomasyon AVM Community welcomes practical experience. Please contact us to share technical observations or corrections.