Siemens 6ES7 194-4AC00-0AA0 ET 200pro CM IM DP Direct Connection Module
6ES7 194-4AC00-0AA0 is the CM IM DP Direct connection module for ET 200pro IM 154-1 DP and IM 154-2 DP interfaces. It provides direct cable connections for PROFIBUS DP and the 24 V supplies. Within Siemens ET 200 distributed I/O systems, it forms the station's incoming connection assembly; the IM interface electronics are a separate component.
What does Direct connection mean?
1L+ and 2L+ supplies use screw terminals, while PROFIBUS conductors use FastConnect insulation displacement terminals. Additional terminals allow the bus and supplies to be looped through. When selecting ET 200 terminal blocks and connection components, distinguish these two termination methods and prepare each cable accordingly.
The housing accommodates up to six M20 cable glands. Among ET 200 connection modules, 6ES7194-4AD00-0AA0 is the DP option with M12 and 7/8-inch connections, while 6ES7194-4AA00-0AA0 uses ECOFAST. Choose according to the installed cabling; changing between these options involves reviewing the wiring arrangement as well as the part number.
PROFIBUS address and bus termination
The PROFIBUS address, from 1 to 125, is selected with DIP switches; a switch also enables the terminating resistor. An address change takes effect after cycling the 1L+ supply. Schedule this during a planned shutdown. When reviewing PROFIBUS and PROFINET interfaces, note that 4AC00 belongs to the PROFIBUS DP connection arrangement.
Record the termination switch position alongside the address during commissioning. Showing the station's position on the bus in the ET 200 system configuration drawing helps explain the original settings during replacement. Compare the physical address setting with the address in the hardware project.
Supply limits and mechanical dimensions
The connection module permits a maximum feed current of 16 A separately for 1L+ and 2L+. However, the permissible load on the ET 200pro internal busbars is limited to 5 A on 1L+ and 10 A on 2L+. When selecting ET 200 power supply modules and power distribution components, calculate connection capacity and internal station loading separately.
The Siemens data sheet specifies 90 × 130 × 100 mm (width × height × depth) and an approximate weight of 292 g. Allow additional room for cable bends and access to the glands; housing dimensions alone do not define the required installation space.
Five checks before selection or replacement
1. Interface match: Record the full IM interface order number together with the connection module code. List CM IM DP Direct and the interface module as separate items in the parts list.
2. Cable suitability: Check that the PROFIBUS cable suits the terminals, and inspect its shield connection and conductor condition. Examine the contact areas before reusing cable ends that have already been disconnected.
3. Address and termination: Photograph the DIP settings before removal. Compare the address with the project record and the termination setting with the actual bus endpoints. Confirm that the network has no duplicate addresses.
4. Station loading: Establish the supply requirements of ET 200 digital input modules, ET 200 digital output modules and ET 200 analog input modules from the actual station parts list. Account for sensor consumption and output loads separately.
5. Post-installation check: Inspect glands, covers, shield contact and cable restraint. After restoring power, check station diagnostics and communication; include other stations receiving looped-through supplies in the maintenance check.
Editor's note: If communication does not return after replacing a connection module, check more than the cable. Compare the old and new DIP settings, project address and bus termination together. One clear photograph taken before removal can prevent unnecessary component replacements.
Manuals and PDF documentation
Use the Siemens ET 200 PDF documentation and user manuals page to find ET 200pro Operating Instructions. Consult the CM IM DP Direct, cable preparation and PROFIBUS address-setting sections. Use the manual appropriate to the station's hardware version for terminal connections and installation procedures.