6ES7 151-3BB21-0AB0
Siemens 6ES7 151-3BB21-0AB0 — IM151-3 PN FO
The Siemens 6ES7151-3BB21-0AB0 is an IM151-3 PN FO interface module for ET 200S. It connects the station's I/O modules to a fiber-optic PROFINET network, passing input data to the PLC and delivering output commands to the station. The main PLC runs the control program; the interface handles communication with the ET 200 station.
Optical Network Connection
FO identifies the fiber-optic version. The module has two optical network ports, making it suitable for installations that use fiber to carry PROFINET traffic. Optical transmission is particularly useful where electrical interference is a concern. When replacing an existing module, check the installed fiber cable and connectors as well as the article number. The connection hardware differs from the copper Ethernet versions in the same family.
This model operates as a PROFINET IO device. For an overview of the available network interfaces, see ET 200 PROFIBUS and PROFINET.
Building the ET 200S Station
The station can be fitted with the digital input, digital output and analog input modules needed by the machine. Field devices such as switches, sensors and valves connect to these I/O modules. The IM151-3 PN FO handles their communication with the controller.
Firmware compatibility matters when adding I/O. For example, Siemens specifies V4.0.1 or later for this interface when used with the 6ES7131-4BF00-0AA0 digital input module or the 6ES7132-4BF00-0AA0 digital output module. Check the requirements for the actual I/O module, especially when extending an older station.
Power and Field Wiring
Choose the power supply modules and power distribution arrangement to suit the connected loads. Keeping track of the supply groups also makes faults easier to trace. The terminal blocks and connection components must match the electronic modules; they provide the connection points for the field wiring.
Engineering and Diagnostics
Siemens lists the V4.0 version of this module among the devices supported from STEP 7 V5.4 SP1. The interface selected in the project, the installed module sequence and the device firmware must agree. Adding expansion modules also means updating the station's hardware configuration.
Extended PROFINET diagnostics are supported from V4.0. Diagnostic information helps investigate communication failures and distinguish network problems from faults associated with the station's I/O.
Use with PROFIsafe
The interface can serve an ET 200S station containing compatible fail-safe I/O modules. A PROFIsafe application also requires an appropriate F-CPU and safety software. The interface carries the safety-related data, while the safety program runs in the controller.
Replacement and Documentation
Siemens documents the 6ES7151-3BB22-0AB0 as a replacement for the 6ES7151-3BB21-0AB0 in an existing installation without changing the hardware configuration. This is useful when sourcing a replacement for an older panel. Keep a copy of the current project and device settings before making the change.
Wiring information, compatibility details and installation documents are available through the Siemens ET 200 PDF and user manuals page. Match the documentation to the 3BB21 suffix on the device label; additional features described for later revisions do not automatically apply to this version.
Related Topics
Functional modules · Counter modules · Positioning modules · Special input modules · Special output modules · Other network interfaces
Navigation: Siemens ET 200 · SIMATIC S7 · Siemens S7 PLC · ET 200 manuals