Siemens Sitop files


Siemens SITOP Files – 6EV and 6EW PDF Archive

The Siemens SITOP files page brings together catalogues, data sheets, connection documents and service manuals used for the 6EV and 6EW models on our site. Some of these legacy devices belong to SIMATIC, SINUMERIK, SIMADYN or SIMOVERT systems. Select the document by the complete order number and system version.

The archive contains 27 different PDFs: 26 manufacturer or UL publications and 1 clearly labelled supplier parts list. Language, edition, page count and scope are shown beside each link. A separate exact-model manual is not available for every one of the 37 models covered.

Quick access: Model documents and battery data sheets | SIMATIC catalogues and system manuals | SINUMERIK connection, installation and service documents | Engineering and historical approval documents | Additional source: supplier parts list | Model pages

Model documents and battery data sheets

+ 6EV3053-0DC operating instructions – PDF
German | GWE 519/021 Jb | 12 pages | 1.98 MB. Exact-model manual; connections, adjustment and loading conditions.

+ 6EV3054-0GC data sheet – PDF
English | 28.04.2018 | 1 page | 0.08 MB. Exact model; does not establish ratings for 0CC/0DC/0FC variants.

+ 6EW1000-7AA data sheet – PDF
English | 20.01.2020 | 1 page | 0.08 MB. Exact-order-number backup battery document.

+ 6EW1000-7AA data sheet – PDF
German | 28.05.2020 | 1 page | 0.09 MB. German manufacturer data sheet for the same model.

SIMATIC catalogues and system manuals

+ SIMATIC C1/C2 – ST 11 catalogue – PDF
German | 1981 / 02.1984 | 108 pages | 18.66 MB. 6EV1322-7AK00 entry and 6EV5101 family information.

+ SIMATIC S5-130/S5-150 – ST 53 catalogue – PDF
German | 1985 / 05.1985 | 144 pages | 16.05 MB. 6EV/6EW supplies and 6EW1000-4AB battery entry; check the full suffix.

+ SIMATIC S5-130W Version B instructions – PDF
German | GWE 548/002 J | 52 pages | 16.17 MB. System and spare-parts document including 6EV3053-0DC.

+ SIMATIC S5-150A central controller instructions – PDF
German | C79000-B8500-C227-2 | 25 pages | 9.81 MB. 6EW1110-5 family reference; the 150A document starts on PDF page 3.

+ SIMATIC S5-90U/S5-95U system manual – PDF
English | 03 / 1994 | 620 pages | 6.17 MB. 6EW1380-1AB ordering entry; system context only for 1AA.

+ SIMATIC S5 – ST 50 archive compilation – PDF
English | 1998 | 500 pages | 5.91 MB. Archive copy with a blank first page; not presented as a complete original catalogue.

SINUMERIK connection, installation and service documents

+ SINUMERIK System 3 service manual – Part 1 – PDF
English | 12.1985 | 320 pages | 16.56 MB. 6EV3054 family reference; not an exact-suffix wiring document.

+ SINUMERIK 805 SW4 installation instructions – PDF
English | 05.1993 | 341 pages | 2.45 MB. Names 6EV3034-0AC; family reference only for 6EV3034-0BC.

+ SINUMERIK 805 SW4 connection conditions – PDF
English | 05.1993 | 162 pages | 3.35 MB. 6EV1352-5BK00 connections and transformer tap information.

+ SINUMERIK 805SM-P connection conditions – PDF
English | 05.1994 | 186 pages | 24.86 MB. 6EV3054-0GC connections; does not establish wiring compatibility with 0DC.

+ SINUMERIK 810/820 GA3 installation instructions – PDF
English | 01.1993 | 413 pages | 2.04 MB. 6EV3055-0BC, front panel and system commissioning information.

+ SINUMERIK 810/820 GA3 connection conditions – PDF
English | 07.1994 | 128 pages | 1.68 MB. 6EV3055-0BC connections; relevant technical pages also carry a 01.1993 revision.

+ SINUMERIK 880 installation instructions – PDF
English | 11.1991 | 720 pages | 4.70 MB. 6EW1861-2 family and system commissioning requirements.

+ SINUMERIK 880 connection conditions – PDF
English | 05.1991 | 218 pages | 6.19 MB. 6EV1352-5BK00, 6EV1363-5AK and related 6EW1861 system information.

+ SINUMERIK 880 GA2 connection conditions – PDF
English | 01.1993 | 322 pages | 6.91 MB. System connection source used for 6EW1861-3AD.

+ SINUMERIK 880 GA2 Anschlussbedingungen – PDF
German | 01.1993 | 320 pages | 7.23 MB. German edition of the GA2 connection conditions.

+ SINUMERIK 880 GA2 installation lists – PDF
English | 01.1993 | 207 pages | 1.66 MB. GA2 system configuration and installation lists.

+ SINUMERIK 840C connection conditions – PDF
English | 09.2001 | 433 pages | 7.99 MB. System context for the 6EW1160-6AA article; not an exact-model circuit diagram.

+ SINUMERIK System 8 start-up checklist – Part 2 PC – PDF
German | 06.1984 | 188 pages | 14.69 MB. Legacy system document used in the 6EW1110-5AC article.

Engineering and historical approval documents

UL documents are historical record copies; they do not establish current certification status or provide service instructions.

+ SINAMICS Low Voltage Engineering Manual V6.5 – PDF
English | 07.2017 | 556 pages | 14.97 MB. SIMOVERT P family context; not a 6EW1890-2AC service manual.

+ UL QQGQ2.E151273 listing record – PDF
English | 08.02.2013 | 5 pages | 0.04 MB. Historical approval record including 6EW1811-8AA and 6EW1861-7AB.

+ UL NRAQ2.E143289 listing record – PDF
English | 07.02.2013 | 2 pages | 0.02 MB. 6EW1811-8AA record; not a wiring or repair manual.

Additional source: supplier parts list

+ TPCOVN SIMATIC parts list – PDF
English | — | 94 pages | 2.32 MB. Supplier list used for 6EV1320-4AC and 6EW1380-0AA research; not a Siemens manufacturer manual.

Editor’s Note

Start with the complete order number and suffix on the label. Similar housings can conceal different inputs, outputs and control connections.

A family manual does not verify every suffix. Check Enable, NC-ON and monitoring terminals against the applicable connection document; do not add undocumented jumpers.

Disconnect power and measure stored capacitor voltage before internal work. Measurements on mains-connected sections require suitably equipped, qualified personnel.

Capacitors, rectifiers, power devices, fans and heat-affected solder joints are general inspection points, not a proven list of recurring faults in these models.

A correct no-load voltage is only the first check. Apply load gradually under the documented cooling and loading conditions, monitoring voltage, ripple and temperature. Test sockets are not load terminals.

Verify battery chemistry and polarity. Do not recharge primary lithium cells. Follow the system manual procedure to preserve backed-up data.

Related model pages

These links open model descriptions; they do not imply that a separate PDF exists for each model. No model PDF was verified and archived in this work for 6EV3032-0AC00, 6EV3114-0AE00-0AA0, 6EW1880-1AA or 6EW1890-6AB.

6EV: 6EV1320-4AC | 6EV1322-7AK00 | 6EV1334-4AK00 | 6EV1336-5AK | 6EV1352-5BK00 | 6EV1363-5AK | 6EV2031-4FC00 | 6EV3032-0AC00 | 6EV3034-0BC | 6EV3053-0DC | 6EV3053-0EC | 6EV3054-0CC | 6EV3054-0DC | 6EV3054-0FC | 6EV3054-0GC | 6EV3055-0BC | 6EV3114-0AE00-0AA0 | 6EV5101-0AC

6EW: 6EW1000-4AB | 6EW1000-7AA | 6EW1110-5AA | 6EW1110-5AB | 6EW1110-5AC | 6EW1110-5AE | 6EW1160-6AA | 6EW1380-0AA | 6EW1380-1AA | 6EW1380-1AB | 6EW1811-8AA | 6EW1861-2AB | 6EW1861-2AD | 6EW1861-3AA | 6EW1861-3AD | 6EW1861-7AB | 6EW1880-1AA | 6EW1890-2AC | 6EW1890-6AB

Related topics

Siemens SITOP main page | 6EV and 6EW models | Power supplies | Used power supplies | Multimeter | Grounding | Capacitors | Short circuit | Fuse

Navigation: Siemens | SITOP | 6EV / 6EW | Türkçe PDF sayfası

External references

Original manufacturer files and document records: Siemens ST 11 | Siemens SINUMERIK 880 | UL E151273 / Siemens | Siemens Engineering Manual