Siemens SINAMICS V90 PN
Siemens SINAMICS V90 PN covers Siemens products through supply class, capacity, command interface and motor feedback. The period references are 05/2018.
Siemens SINAMICS V90 PN supports maintenance, machine retrofit and new-axis selection. The drive forms one system with the motor winding, encoder protocol, command interface, brake and cable terminations.
For Siemens SINAMICS V90 PN, SINAMICS V90 — D33 Basic Servo Drive System identifies the manual family used to locate generation and combination tables.
Siemens SINAMICS V90 PN uses PROFINET as its connection profile. Commissioning and service use SINAMICS V-ASSISTANT.
V90 PN receives axis commands over PROFINET. Its UF suffix introduces PLC technology-object, telegram, device-name/IP and cycle-time choices that do not belong to the PTI version.
When building a Siemens SINAMICS V90 PN axis, consider Siemens SINAMICS V90 PTI, Siemens SINAMICS S210 (First Generation) and Siemens SINAMICS V80 within the same generation and supply class.
For Siemens SINAMICS V90 PN command, feedback and maintenance, Siemens SIMODRIVE 611 analog, Siemens SIMODRIVE 611 digital and Siemens SIMODRIVE 611 universal complete the system through matching ports, cable ends and software support.
Siemens SINAMICS V90 PN family and model distinctions
6SL3210-5FB10-1UF1: Siemens SINAMICS V90 PN. Key distinctions include 240 VAC, 0.1 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FB10-2UF1: Siemens SINAMICS V90 PN. Key distinctions include 240 VAC, 0.2 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FB10-4UF1: Siemens SINAMICS V90 PN. Key distinctions include 240 VAC, 0.4 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FB10-8UF0: Siemens SINAMICS V90 PN. Key distinctions include 240 VAC, 0.75 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FB11-0UF1: Siemens SINAMICS V90 PN. Key distinctions include 240 VAC, 1 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FB11-5UF0: Siemens SINAMICS V90 PN. Key distinctions include 240 VAC, 1.5 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FB12-0UF0: Siemens SINAMICS V90 PN. Key distinctions include 240 VAC, 2 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FE10-4UF0: Siemens SINAMICS V90 PN. Key distinctions include 480 VAC, 0.4 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FE10-8UF0: Siemens SINAMICS V90 PN. Key distinctions include 480 VAC, 0.75 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FE11-0UF0: Siemens SINAMICS V90 PN. Key distinctions include 480 VAC, 1 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FE11-5UF0: Siemens SINAMICS V90 PN. Key distinctions include 480 VAC, 1.75 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FE12-0UF0: Siemens SINAMICS V90 PN. Key distinctions include 480 VAC, 2.5 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FE13-5UF0: Siemens SINAMICS V90 PN. Key distinctions include 480 VAC, 3.5 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FE15-0UF0: Siemens SINAMICS V90 PN. Key distinctions include 480 VAC, 5 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
6SL3210-5FE17-0UF0: Siemens SINAMICS V90 PN. Key distinctions include 480 VAC, 7 kW. Confirm wiring, feedback and system compatibility against the complete catalog number.
A shared enclosure or series name is insufficient when replacing Siemens SINAMICS V90 PN. Compare the complete nameplate sequence, supply voltage, capacity, motor-encoder generation, brake, connector and parameter-transfer path together.