Siemens 6ES5 752-0AA22 — V.24/V.28 RS-232C Interface Submodule
Siemens 6ES5 752-0AA22 is a V.24/V.28 — RS-232C interface submodule for SIMATIC S5. It has a 25-pin Sub-D front connection and a documented maximum transmission rate of 19,200 bit/s. As part of the S5 interface module family, it provides the RS-232 electrical interface in a compatible CPU or CP submodule slot.
With the appropriate configuration, it supports serial data exchange with terminals, printers, computers or other controllers. In industrial communication, the submodule provides the electrical connection; the host CPU or CP handles the protocol, data format and communication jobs.
Supported CPUs and communications processors
Siemens documentation lists the V.24 submodule for CP 524. For CP 524 models such as 6ES5 524-3UA13 and 6ES5 524-3UA15, check the processor’s hardware version, installed driver and interface slot before selecting a replacement.
Documented applications also include CP 544, CP 544B, and compatible submodule positions on CPU 928B and CPU 948. 752-0AA22 is not a standalone communications processor; it supplies the electrical layer of the serial interface.
25-pin connection and cable wiring
The main assignments are 2: TxD output, 3: RxD input, 4: RTS output, 5: CTS input and 7: GND. Additional status signals are available, so select the S5 cable and connectors against the partner device’s wiring diagram. Connect TxD to the partner’s RxD; connector pin numbers do not necessarily match at both ends.
Pin 7 is the signal reference. Treat grounding and shield termination separately from signal GND. Siemens instructs that casing ground and GND must not be arbitrarily connected together, and that signal GND must be connected at both ends.
Speed, cable length and RTS/CTS
The CP 544 V.24 specifications state 300–19,200 bit/s, a maximum 16 m shielded cable and metal connector housings. Submodule consumption is 0.3 A maximum at 5 V, with 1.5 W maximum power loss. Set the operating rate within the limits of the host device and installed driver.
Both ends must agree on baud rate, data bits, parity and stop bits. Also verify the protocol and send/receive jobs in the PLC program. Siemens’ standard RK 512 and 3964/3964R applications do not use the control lines; RTS/CTS flow control is an option with the open driver. Do not assume every connection requires handshake jumpers.
AA22 versus AA23 and other 752 variants
On AA22, J3 controls transmit polarity, J5 receive polarity, J6 the accepted receiver levels, and J9 the CTS path. The Siemens manual specifically states that J6 has no function on 6ES5 752-0AA23. Do not transfer jumper assumptions unchanged between AA22 and AA23.
6ES5 752-0AA12 provides a 20 mA TTY interface, 6ES5 752-0AA43 provides RS-422-A/RS-485, and 6ES5 752-0AA53 is a PG submodule. Membership of the same 752 family does not establish identical wiring or electrical compatibility.
Troubleshooting and used-part assessment
During PLC communication troubleshooting, confirm the physical interface, cable pinout, jumper settings and serial parameters before investigating the protocol. Check for electromagnetic interference, poor shield connections and damaged connectors. Verify transmission and reception separately during testing.
Editor’s note
When ordering this submodule, provide more than “RS-232 required.” Identify the Siemens S5 host and the device at the other end. Getting the submodule, slot and cable right together saves considerable troubleshooting later.
If transmitted data never appears at the other end, give the cable a fair check before condemning the card. Trace TxD and RxD end to end. A label saying “working cable” does not establish that it suits the two devices now connected.
Before fitting a spare, photograph J3, J5, J6 and J9. A previous installation may have required different settings. Those small differences can make a serviceable submodule appear faulty.
Avoid solving RTS/CTS questions by habit. A link that worked in one project may be inappropriate in another. Identify the driver and flow-control settings first, then decide how the cable should be wired.
For a used part, ask about a send-and-receive test, not just a successful power-up. Request clear photographs of the label, connector and jumper area. Include the full part number, quantity and intended CPU or CP when enquiring.
OtomasyonAVM resources and PDFs
+ S5 interface modules and S5 communications processors: check the submodule and host together.
+ OtomasyonAVM S5 PDF archive: related system documents. The English manufacturer manuals below cover pin assignments, jumpers and applications.
Related topics
+ 6ES5 752-0AA23 — V.24 variant with a different J6 function
+ 6ES5 752-0AA12 — 20 mA TTY interface
+ 6ES5 752-0AA43 — RS-422-A/RS-485 interface
+ 6ES5 752-0AA53 — PG submodule for CPU 928B/948
Browse SIMATIC S5
+ S5 communications processors
Siemens and external references
+ Siemens CP 544 Manual — English; pp. 10-29–10-38: V.24 wiring, jumpers and specifications