6ES5 948-3UA13
Siemens 6ES5 948-3UA13 – CPU 948-1, S5-155U, 640 KB RAM
Siemens 6ES5 948-3UA13 is the CPU 948-1 central processing unit for S5-155U in the SIMATIC S5 family. It provides 640 KB of internal user RAM, a single-slot housing, a PG connection and a receptacle for a second serial interface submodule. In Siemens S5 systems it executes the program, processes data and coordinates peripheral equipment.
The Siemens system manual covers this hardware under CPU 948B -3UA13. The related 6ES5 948-3UA23 is the CPU 948-2 with 1664 KB of user RAM. When comparing nearby order numbers such as 6ES5 948-3UA11 and 6ES5 948-3UA12, check physical construction, hardware revision and the existing project as well as memory capacity.
RAM, Flash card and backup
The 640 KB RAM is internal working memory for the user program and data. A 374 Flash EPROM card can provide external program/data storage. When selecting S5 memory cards, verify the complete card order number and CPU compatibility. A Flash card does not increase internal RAM by its storage capacity.
RAM retention must be assessed together with the system's backup arrangement. Check the S5 power supply and backup battery before assuming data will survive a power interruption. The manual associates automatic copying from the Flash card into internal RAM with an overall reset; an ordinary power cycle is not necessarily the same operation.
Electrical and mechanical specifications
The relevant table specifies supply rails of 5 V DC ±5% and 24 V DC +25%/−17%. Typical current at 5 V is 1.5 A. These are CPU supply requirements within the rack connection arrangement. The 24 V figure must not be interpreted as permission to power arbitrary module terminals externally.
Dimensions are 20.32 × 233.4 × 160 mm (width × height × depth), weight approximately 0.6 kg, and protection IP00. The CPU 948B -3UA13 occupies one slot in the central rack. Position, ventilation and environmental requirements follow the S5-135U/155U central controller's installation rules.
SI1 PG connection and optional SI2
The front panel has a 15-pin SI1 PG interface. The specified serial PG transmission rate is 9600 bit/s. With S5 programming cables, match the electrical interface as well as the connector. The same SI1 can be accessed through its front connector or a suitable 923C coordinator arrangement; these paths do not operate as two independent PG ports simultaneously.
The physical function of the second serial interface, SI2, depends on the installed submodule. Select a suitable option from the S5 interface submodules. For a second PG/operator-panel connection, the manual requires a PG submodule; 6ES5 752-0AA53 is a related option. An empty receptacle must not be treated as an operational communication port.
With the appropriate submodule and software configuration, options include RK 512, 3964/3964R, open driver or SINEC L1. When assessing S5 communication modules and connected devices, verify the physical interface, protocol and project settings together. Inspect which submodule, if any, is actually fitted to a used CPU.
Program execution, I/O and addressing
The CPU supports cyclic, time-controlled and interrupt-driven program execution. The technical table specifies 256 timers and 256 counters. Up to 1024 digital inputs and 1024 digital outputs are listed within the process image. These are system capacity figures; field signals connect through suitable S5 digital input and S5 digital output modules.
When reviewing the STEP 5 program, check I/O addresses, data blocks and peripheral module allocation together. Back up existing blocks and relevant parameters using suitable S5 programming software. Having a program file alone does not establish that every current plant data value has also been preserved for a CPU replacement.
Status LEDs and maintenance
The front panel includes RUN, STOP, SYS FAULT, QVZ, ADF, ZYK, BASP, SI1 and SI2 indicators. For example, ZYK relates to cycle-time monitoring, ADF to addressing, and BASP to command output inhibition. During PLC troubleshooting, interpret the LED state together with CPU diagnostics and the program's last activity. A single indicator does not automatically establish a CPU hardware fault.
Model and hardware revision differences matter when selecting a spare. 3UA13 is a standard S5-155U CPU; it must not be treated as the same product as a 948R/UR-coded S5-155H processor. Check single- or multiprocessor operation, rack and any coordinator arrangement against the existing project.
When buying a used PLC CPU, inspect the label and revision, RAM/program status, memory-card receptacle, SI1 connection and any SI2 submodule. For used Siemens automation equipment, a test based solely on the RUN LED is insufficient; verify program transfer and the communication functions needed by the application.
For modernization projects, Derell PLC and control options may also be assessed against the application's requirements. A CPU 948 system requires separate comparison of memory, execution behaviour, interrupts, I/O structure and existing communications. This link is not a direct CPU 948 substitution or an equivalent-performance recommendation.
Editor's Note
Before removing a working CPU, photograph the complete label, hardware revision, fitted memory card and interface submodule. Similar digits do not establish an identical unit. For this model, verify the 640 KB capacity and single-slot construction together.
Start by backing up the program and required current data. A fitted Flash card does not prove that it contains the latest program. Changes made at the plant may exist only in RAM, so compare the card contents with the running application.
Remember the battery and rack power supply. After a power-related failure, check the backup arrangement, supply and module connections as well. Follow the relevant maintenance procedure and data-retention requirements before removing a battery or CPU from a working installation.
A green RUN LED is not the end of the test. Verify online PG access, the correct running program and required communication. If SI2 needs a submodule, establish whether it is included. Keep the cover fitted where the receptacle is unused.
Do not use OV RESET merely to clear a fault indication. An overall reset erases RAM areas; have the backup and recovery source ready beforehand. For a spare, the most useful evidence is a test in the relevant configuration and a clear record of the memory/interface parts supplied.
OtomasyonAVM resources and PDF archive
Siemens 6ES5 948-3UA13 main page · Used Siemens S5 models · OtomasyonAVM S5 PDF archive
The S5-135U/155U System Manual, C79000-G8576-C199-07 below covers 3UA13/3UA23 hardware in section 5.1. The exact-model Siemens data sheet and the manual's A-4 ordering table confirm 640 KB RAM for 3UA13. The documents are in English.
Related topics
6ES5 948-3UA11 · 6ES5 948-3UA12 · 6ES5 948-3UA23 · Derell PLC options
Navigation
SIMATIC S5 · S5 memory cards · S5 interfaces · S5 cables · Used PLC CPUs
External references
Siemens 6ES5948-3UA13 data sheet – exact model, S5-155U and 640 KB RAM (English; archived copy of the manufacturer's document).
Siemens S5-135U/155U System Manual – CPU 948B, printed page 5-2 · SI1/SI2 interfaces, printed page 5-13.
Electrical and mechanical data, printed pages 5-15–5-16 · Complete CPU order numbers, printed page A-4.