6ES5 941-7UA11
Siemens 6ES5 941-7UA11 CPU 941 – SIMATIC S5-115U Processor
Siemens 6ES5 941-7UA11 is an early A-series CPU 941 processor for SIMATIC S5-115U. It executes a RAM-based user program using STEP 5 instructions and manages modular I/O and machine sequences. Within the SIMATIC S5 family, select this model for Siemens S5 PLC maintenance by checking the complete order number together with the software version.
Memory structure and capacity units
In the CPU 941 A family, consider internal RAM together with the fitted memory submodule. Instruction count and byte capacity are different units. The A-series manual explains that a STEP 5 instruction normally occupies two bytes; “1 K instructions” must not be read as “1 KB”. Verify usable capacity against the actual CPU version and installed memory.
When reviewing S5 memory modules, check the type, programming number and version requirements of codes such as 6ES5 375-0LA15, 6ES5 375-0LA21 and 6ES5 375-0LC31. Do not assume that every card in the 375 family provides the same usable capacity or operates in the same way with this CPU.
EPROM/EEPROM and RAM behave differently when power is removed. Battery backup matters for retaining programs and data in RAM. Before replacement, compare the memory submodule contents with a PG backup of the program currently running.
STEP 5 and the programming connection
Programming and diagnosis use STEP 5. The CPU 941 A family’s serial connection serves a PG and suitable SINEC L1 arrangements. Assess S5 cables and connectors together with a TTY-compatible programming adapter; a similar connector does not establish direct RS-232 compatibility.
Where S5 communication modules or S5 interface modules are installed, review the relevant system blocks and hardware connections during CPU replacement. Entering RUN alone does not demonstrate correct operation of every existing communication task.
Power supply and rack installation
The CPU operates from the S5-115U backplane’s internal 5 V supply. Assess S5 power supply capacity against the combined load of the CPU, memory and other modules. Record the complete code and battery condition of existing units such as 6ES5 951-7LB14 PS 951.
Central rack options such as 6ES5 700-0LA12 and 6ES5 700-1LA12 provide a designated CPU position. Compare the actual rack code, expansion connections and module arrangement before replacement; mechanical similarity alone is insufficient. Remove and insert modules with power switched off.
I/O and address checks
Field signal voltages and channel counts depend on the installed S5 digital input, S5 digital output and S5 analog modules. Treat the processor separately from signal modules and distinguish physical channels from program address areas.
When commissioning a replacement CPU, review startup behaviour, timer/counter values and retained data requirements as well as program blocks. The machine must resume from the intended sequence; complete testing under controlled field conditions.
Distinguishing UA11, UA12, UA13 and UB11
6ES5 941-7UA12, 6ES5 941-7UA13 and 6ES5 941-7UB11 are separate order numbers. In particular, do not transfer B-series current consumption, instruction times or software features directly to UA11. Base replacement decisions on the complete code, hardware version, operating system, memory and existing project.
Document scope: The detailed CPU 941 table in the available A-series manual identifies 7UA13. Its current, weight, instruction-time and maximum memory-expansion figures are therefore not presented here as confirmed UA11 specifications. Siemens’ exact-code model list verifies UA11 as CPU 941 for S5-115U.
Editor’s Note
Keep the final order-number digits in view. “CPU 941” alone is insufficient. Photograph the 7UA11 label, hardware version and installed memory, then compare the replacement against that record.
Secure the working program first. Back up the program read through the PG and compare it with the memory copy. Check battery condition and review causes of memory data loss; do not assume the RAM program will survive a power interruption.
A failed PG connection does not immediately mean a failed CPU. Check the TTY adapter, cable and connector contacts. Trying a known working connection set can prevent rejecting a sound processor because of an unsuitable cable.
Have the supply checked under load. Power at the rack does not prove that the CPU receives a stable supply. Check the power supply, backplane contacts and battery before treating STOP as a processor hardware fault.
Do not finish testing at the green light. Check program reading, controlled RUN/STOP transitions, I/O behaviour and any communication together. Save diagnostics and backups before an overall reset; record the supplied memory and actual test results clearly.
OtomasyonAVM resources and PDFs
See About Siemens S5 PLC and the S5 PDF archive for series information and documents. For the A series, use S5-115U Gerätehandbuch, 6ES5 998-0UF12, Ausgabe 03, GWA 4NEB 811 6000-01b. This document is in German; the later B-series manual is not an exact UA11 datasheet.
Related topics
CPU 941-7UA12 · CPU 941-7UA13 · CPU 941-7UB11 · S5 memory modules · S5 power supplies. These links support further review and do not confirm direct interchangeability.
Navigation: 6ES5 941-7UA11 main page | Used Siemens models | Siemens S5 PLC | SIMATIC S5
Siemens and external references
Siemens S5-115U A-series CPU manual – 6ES5 998-0UF12, Ausgabe 03 (German). The CPU 941 family description is on printed page 2-18, the memory table on 2-22 and the detailed 7UA13 table on 15-12.
Siemens migration guide from S5 to S7-1500 – Entry 105106251, V1.0, 04/2015 (English). Table 7-1 lists 6ES5 941-7UA11 as S5-115U CPU 941; the comparison table does not approve a plug-and-play replacement.