6ES5 581-1EB11

Siemens 6ES5 581-1EB11 – CP 581/486 Basic Board with Silicon Disk

Siemens 6ES5 581-1EB11 is a CP 581/486 basic computer board used in Siemens S5 PLC systems. It fits into the SIMATIC S5 rack and features an 80486SL processor running at 33 MHz, 4 MB DRAM and a 2 MB onboard flash silicon disk. Approximately 1.3 MB of the silicon disk is available to the user.

Typical applications involve collecting process data, processing records and managing machine data on the PC side. The board shares tasks with the S5 CPU that executes the control program. When reviewing S5 communications modules and S5 special modules, remember that this board is a computer component with its own software and stored data.

Processor, memory and silicon disk

Working memory and the silicon disk serve different purposes. DRAM supports program execution, while the onboard flash disk operates as a hard disk in the MS-DOS environment. When selecting from S5 memory cards, capacity alone is insufficient: the storage type supported by the CP 581 and the structure expected by its software must also be checked.

Within the same 486 family, 6ES5 581-0EB11 is the basic board without an onboard silicon disk. 6ES5 581-1EA11 and 6ES5 581-0EA11 belong to a different processor generation of CP 581 boards. The CP 581 family name alone does not identify a suitable replacement for 1EB11.

Storage and expansion components

With suitable software installed, the onboard silicon disk allows operation without a separate mechanical mass storage module. In installations using additional storage, 6ES5 581-0LA11 and 6ES5 581-1LA11 are separate components. For AT-board expansion, the manual identifies 6ES5 581-0RA12 for the CP 581/486; its suffix must be distinguished from 6ES5 581-0RA11.

Connections and addressing

Data exchange with the CPU takes place over the S5 backplane bus. Computer peripheral connections include COM 1/3, KEYB/COM 2 and monitor connections. Keep its role distinct from S5 interface modules. When selecting S5 cables and connectors, use the appropriate CP 581 Y adapter and the pin assignments in the manual.

Addressing and commissioning require the rack position, BIOS/SETUP configuration and CPU-side data exchange to be considered together. Check the existing project records before copying settings from another cabinet. Record the startup display, RUN/STOP/FAULT indications and communication with the CPU as separate items in the test report.

S5 system compatibility and installation

The Siemens manual covers S5-115U, S5-135U, S5-155U and S5-155H systems for the CP 581 family. Suitability depends on the S5 rack and permitted slot arrangement. S5-115U installation requires an adapter casing and a 5 V/15 A S5 power supply. Use with CPU 921 in an S5-135U system is not permitted.

Similar order numbers do not establish interchangeability. When comparing nearby versions such as 6ES5 581-1EB12 and 6ES5 581-1EC12, assess the nameplate, board revision, installed memory, BIOS and application software together. Successful startup must be followed by verification that the machine receives the expected data.

Prepare maintenance records using the system-identification approach described in About Siemens S5 PLC. When assessing Siemens automation spare parts, request details of storage, adapters, connecting cables and startup information alongside photographs of the bare board. A missing accessory can prevent an otherwise serviceable board from being used on site.

Editor's Note

Start with the full nameplate: 6ES5 581-1EB11. Avoid rushing into a purchase based only on the CP 581 family name. Photograph the front panel, board and fitted components, then compare them with the existing installation.

A successful power-up is encouraging, but the check should continue. Inspect the BIOS display, reported memory and detected drives. Then run the application and verify communication with the CPU; one startup photograph cannot establish the condition of the complete system.

Files on the silicon disk may be essential to a machine that has operated for many years. Back them up before formatting, reinstalling software or deleting files. Preserve any separate hard disk as well, and assess the software together with the hardware.

If there is no picture, check the monitor, cable and Y adapters before condemning the board. Bent pins, loose connections or a missing adapter can consume considerable troubleshooting time while appearing to be an electronic fault.

Finally, document the working SETUP configuration and connection arrangement. Understand the existing installation before changing settings on the old board. A useful spare combines the correct order number with preserved software and a verified connection arrangement.

OtomasyonAVM resources and PDF files

Browse S5 expansion modules for related components and the S5-115 PDF files archive for shared documentation. Use the applicable CP 581 manual revision for installation.

Related topics

6ES5 581-0EB11 · 6ES5 581-1EA11 · 6ES5 581-0RA12 · 6ES5 581-1LA11

S5 section menu

Siemens S5 PLC · SIMATIC S5 · S5 racks · S5 power supplies · S5 cables and connectors · S5 memory cards

External references

Siemens CP 581 Manual, Volume 1 – manufacturer manual (archived copy). Exact order number: p. 2-5; board design: p. 3-7; silicon disk: p. 3-72; technical data: p. 4-6; installation: pp. 2-39–2-42.