Siemens G120 fault codes

Siemens G120 Frequency Converter: Alarm and Fault Management

Parameters and Settings
- Alarm and Fault Codes: Displayed with parameters like r2122, r0945.
- Alarm and Fault Values: Additional information is displayed with parameters like r2124, r0949.
- Time Information: Alarm/fault times are displayed with parameters like r2123, r2125, r0948, r2109.
- Extended Settings: The behavior of specific alarms/faults can be modified with parameters like p2118, p2119.

 F01000: Internal software error. (more detail >>)
 F01001: FloatingPoint exception. (
more detail >>)
 F01015: Internal software error. (
more detail >>)
 F01018: Power-up aborted more than once. (
more detail >>)
 A01028: Configuration error. (
more detail >>)
 F01033: Unit switchover: Reference parameter value invalid. (
more detail >>)
 F01034: Unit switchover: Calculation of the parameter values after reference value change unsuccessful. (
more detail >>)
 F01040: Parameters must be saved. (
more detail >>)
 F01044: Loading memory data card defective. (
more detail >>)
 F01105: CU: Insufficient memory. (
more detail >>)
 F01122: Frequency at the probe input too high. (
more detail >>)
 F01205: CU: Time slice overflow. (
more detail >>)
 F01250: CU hardware fault. (
more detail >>)
 F01512: An attempt has been made to establish a conversion factor for scaling which does not exist. (
more detail >>)
 A01590: Motor maintenance interval elapsed. (more detail >>)
 F01600: STOP A initiated. (
more detail >>)
 F01625: Sign-of-life error in the Safety data. (
more detail >>)
 F01650: Acceptance test required. (
more detail >>)
 F01659: Write task for parameter rejected. (
more detail >>)
 F01662: Error, internal communications. (
more detail >>)
 A01666: Static 1 signal at the F-DI for safe acknowledgement. (
more detail >>)
 A01698: Commissioning mode active for safety functions. (
more detail >>)
 A01699: Switch-off signal path test required. (
more detail >>)
 A01900: PROFIBUS: Configuration telegram faulty. (
more detail >>)
 A01910 / F01910: Fieldbus SS setpoint timeout. (
more detail >>)
 A01920: PROFIBUS: Cyclic connection interrupt. (
more detail >>)
 F03505: Analog input, wire break. (
more detail >>)
 A03520: Temperature sensor fault. (
more detail >>)
 A05000, A05001, A05002, A05004, A05006: Power Module overtemperature. (
more detail >>)
 F06310: Supply voltage (p0210) incorrectly parameterized. (
more detail >>)
 F07011: Motor overtemperature. (
more detail >>)
 A07012: I2t motor model overtemperature. (
more detail >>)
 A07015: Motor temperature sensor alarm. (
more detail >>)
 F07016: Motor temperature sensor fault. (
more detail >>)
 F07086, F07088: Unit switchover: Parameter limit violation. (
more detail >>)
 F07320: Automatic restart aborted. (
more detail >>)
 A07321: Automatic restart active. (more detail >>)
 F07330: Search current measured too low. (
more detail >>)
 A07400: VDC_max controller active. (
more detail >>)
 A07409: V/f control, current limiting controller active. (
more detail >>)
 F07426: Technology controller actual value limited. (
more detail >>)
 A07444: PID autotuning is activated. (
more detail >>)
 F07445: PID autotuning canceled. (
more detail >>)
 F07801: Motor overcurrent. (
more detail >>)
 A07805: Drive: Power unit overload I2t. (
more detail >>)
 F07807: Short-circuit detected. (
more detail >>)
 A07850: External alarm 1. (
more detail >>)
 F07860: External fault 1. (
more detail >>)
 F07900: Motor blocked. (
more detail >>)
 F07901: Motor overspeed. (
more detail >>)
 F07902: Motor stalled. (
more detail >>)
 A07903: Motor speed deviation. (
more detail >>)
 A07910: Motor overtemperature. (more detail >>)
 A07920: Torque/speed too low. (
more detail >>)
 A07921: Torque/speed too high. (
more detail >>)
 A07922: Torque/speed out of tolerance. (
more detail >>)
 F07923: Torque/speed too low. (
more detail >>)
 F07924: Torque/speed too high. (
more detail >>)
 A07927: DC braking active. (
more detail >>)
 A07980: Rotary measurement activated. (
more detail >>)
 A07981: No enabling for rotary measurement. (
more detail >>)
 A07991: Motor data identification activated. (
more detail >>)
 F08501: Setpoint timeout. (
more detail >>)
 F08502: Monitoring time, sign-of-life expired. (
more detail >>)
 F08510: Send configuration data not valid. (
more detail >>)
 A08511: Receive configuration data not valid. (
more detail >>)
 A08526: No cyclic connection. (
more detail >>)
 A08565: Consistency error affecting adjustable parameters. (
more detail >>)
 F13100: Know-how protection: Copy protection error. (
more detail >>)
 F13101: Know-how protection: Copy protection cannot be activated. (
more detail >>)
 F30001: Overcurrent. (
more detail >>)
 F30002: DC-link voltage overvoltage. (
more detail >>)
 F30003: DC-link voltage undervoltage. (
more detail >>)
 F30004: Inverter overtemperature. (
more detail >>)
 F30005: I2t inverter overload. (
more detail >>)
 F30011: Line phase failure. (
more detail >>)
 F30015: Motor cable phase failure. (
more detail >>)
 F30021: Ground fault. (
more detail >>)
 F30022: Power Module: Monitoring VCE. (more detail >>)
 F30027: Time monitoring for DC link precharging. (
more detail >>)
 F30035: Overtemperature, intake air. (
more detail >>)
 F30036: Overtemperature, inside area. (
more detail >>)
 F30037: Rectifier overtemperature. (
more detail >>)
 A30049: Internal fan defective. (
more detail >>)
 F30052: Incorrect Power Module data. (
more detail >>)
 F30053: Error in FPGA data. (
more detail >>)
 F30059: Internal fan defective. (
more detail >>)
 F30074: Communications fault between Control Unit and Power Module. (
more detail >>)
 A30502: DC link overvoltage. (
more detail >>)
 F30662: CU hardware fault. (
more detail >>)
 F30664: CU power up aborted. (
more detail >>)
 F30850: Software fault in the Power Module. (
more detail >>)
 A30920: Temperature sensor fault. (
more detail >>)
 A50001: PROFINET configuration error. (
more detail >>)
 A50010: PROFINET name of station invalid. (
more detail >>)
 A50020: PROFINET: Second control missing. (more detail >>)

+ G120C User Manuals

+ G120C Error Index

+ G120C Error Codes 2

+ G120C Error Codes 3

+ G120C Error Codes 4

+ G120C Error Codes 5

+ G120C Error Codes 6

++ Siemens Homepage 

Reminder: Siemens G120 and other Siemens drive are available for sale at Otomasyon Mall. Please note that some devices are used products, so take this into consideration when purchasing. Once these products are out of stock, new ones will not be restocked. The information above is based on general knowledge and does not guarantee accuracy. For more detailed and precise information, it is recommended to refer to the relevant device’s user manual. (04.09.2011)

Please Note: The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please feel free to share them with us!    


Your shopping cart is empty!