6ES7 138-4FC01-0AB0

6ES7 138-4FC01-0AB0 is the Siemens SIMATIC ET 200S 4 F-DI / 3 F-DO PROFIsafe electronic module. It combines fail-safe digital input and output functions in a 30 mm wide housing. Operating at 24 V DC, the module can support applications up to SIL 2 / Category 3 / PL d when the relevant system requirements are met. Related products are available in our Siemens ET 200 PROFIsafe section.

Device Description and Application

The 4 F-DI / 3 F-DO arrangement combines safety-related signal acquisition and output control within one station. Selection involves more than comparing channel counts: field devices, the control program, wiring and the machine's required stopping behaviour must be considered together.

The stated SIL and PL ratings do not automatically establish the safety performance of the complete machine. The PLC, sensors, actuators and safety function must be validated for the application. When replacing a component in an existing ET 200 station, refer to the approved project's hardware and software records.

Technical Data

Manufacturer: Siemens
Order number: 6ES7138-4FC01-0AB0
System family: SIMATIC ET 200S
Designation: 4 F-DI / 3 F-DO DC24V/2A PROFIsafe
Fail-safe inputs: 4
Fail-safe outputs: 3
Rated voltage: 24 V DC
Permissible supply range: 20.4–28.8 V DC
Rated output current: 2 A per channel, subject to total-current limits
Typical input current at signal “1”: 3.5 mA
Typical power loss: 3.5 W
Dimensions: 30 × 81 × 52 mm — width × height × depth
Maximum achievable safety level: SIL 2 / Category 3 / PL d

Total output current: With horizontal installation, 6 A up to 40 °C and 4 A up to 60 °C; with vertical installation, 4 A up to 40 °C. Account for the actual cabinet temperature and simultaneous loads. When selecting a power supply or DIN rail power supply, assess the complete load arrangement.

How the Four Fail-Safe Inputs Are Arranged

The module's eight physical inputs form four fail-safe inputs using 1oo2 evaluation. The pairs are DI0–DI4, DI1–DI5, DI2–DI6 and DI3–DI7. Follow each pair together when reviewing the wiring diagram.

Check that each sensor and its output arrangement are suitable for the safety application. Label cables and connectors so that paired channels can be traced in the installation. When comparing this product with general digital input modules, assess the safety requirements separately.

P/M-Switching Outputs

P/M switching switches both sides of the load circuit. Connect the load between the corresponding DOx P and DOx M terminals. Do not bridge the switched M path by connecting it directly to common 0 V; follow the manufacturer's circuit diagram.

Consider load pickup and release behaviour as well as nominal current. Where external relays and sockets are used, assess their role in the safety function and any feedback requirements. Review the actual circuit rather than transferring wiring practices from other ET 200 digital output modules.

Terminal Bases and Hardware Compatibility

The manual lists TM-E30S44-01, TM-E30C44-01, TM-E30S46-A1 and TM-E30C46-A1 terminal bases. Check the installed base's label before ordering. Related products are listed under ET 200 terminal blocks.

The manufacturer's product description also identifies PROFINET use with a suitable IM151-3 HF. Check the exact reference and version of the project's communication interface. Review the PROFIBUS or PROFINET network together with the safety configuration. Other station components can be found in our ET 200 connection modules section.

Configuration and Legacy Software Notice

The module's PROFIsafe address must match the hardware configuration. Record the address, component reference and project version before replacement. Assess the effect of timing changes on the safety function's response time rather than adjusting parameters solely to clear a diagnostic message.

Legacy projects using STEP 7 Safety Advanced V11: Siemens issued a notice concerning certain combinations of the discrepancy behaviour and reintegration after discrepancy error parameters. The effective behaviour can differ from the configured settings. When reviewing a project configured or compiled with this version, consult Siemens product warning A5E31857732-AA and check its stated applicability.

Fault Checks and Commissioning

SF and channel LEDs are not safety signals. Evaluate diagnostic records, field wiring and project status together during fault investigation. Reintegrate the affected function only after correcting the cause and validating the relevant safety function.

Before installation, safely isolate the relevant energy sources. Inspect terminal contacts, housing condition and cable identification. Cable ducts and other control panel components should leave connections accessible. Establish conditions that prevent unexpected machine movement during testing, and retain the changes and test results in the maintenance record.

Editor's Recommendations and Related Topics

Start replacement selection with the complete order number and approved project record. A similar label or matching channel count does not establish interchangeability. Confirm whether the supplied electronic module includes a terminal base or other accessories.

For a used safety module, appearance or a power-on check cannot replace validation of the safety application. Assess its history and condition alongside its suitability for the system. Our Siemens ET 200 overview provides background on the product family.

User Manuals and PDF Documents

+ Siemens ET 200 user manuals — PDF archive page.
+ Siemens 6ES7 138-4FC01-0AB0 user manual — ET 200S fail-safe modules manual, section 7.6; PDF page 157.
+ 4 F-DI / 3 F-DO terminal assignments — PDF page 161.
+ ET 200S fail-safe modules supplementary product information — Manual additions and corrections dated July 2022.
+ Siemens ET 200 general catalogue archive — Use the device manual above for model-specific applications.

++ Siemens Automation Main Page
++ Siemens Automation Contact — For enquiries to Otomasyon AVM.

Reminder: Confirm current availability, condition and scope of supply for Siemens 6ES7 138-4FC01-0AB0 before purchasing. Some devices offered by Otomasyon AVM are used products; review the individual descriptions and photographs. Products will not be restocked once available stock is exhausted.

Note: The information, commissioning suggestions and documents on this page are provided for general guidance, are non-binding and may be updated. Safety applications must be based on manufacturer documentation, risk assessment and a validated project. The Otomasyon AVM Community welcomes practical feedback. You can share your operating experience and suggestions with us.