6ES5 927-5BA13

Siemens 6ES5 927-5BA13 – S5-150A CPU 927 Central Processing Board

Siemens 6ES5 927-5BA13 is a 927 central processing board for the SIMATIC S5-150A central controller. Siemens' commissioning document identifies it as “Zentralbaugruppe 3”, the third central board. This Siemens automation board forms part of the Siemens S5 PLC multi-board CPU assembly; during SIMATIC S5 servicing, it should be identified as a component of that assembly.

Its distinctive features include the operating-system EPROM arrangement and associated control jumpers. User-program memory boards, the other central boards and the programming interface are separate components. For replacement, compare the 5BA13 order-number suffix, hardware revision and EPROM labels together.

How the 925, 926 and 927 boards work together

Siemens' relevant table identifies 6ES5 925-5AA12 as central board 1, 6ES5 926-5AA12 as central board 2, and 6ES5 927-5BA13 within the central board 3 group. These boards perform different duties. Fault assessment should include the assembly's power supply, backplane connections, memory configuration and interaction with the other central boards.

6ES5 927-5BA12, 6ES5 927-3KA13 and 6ES5 927-3SA11 have similar numbers but are different order codes. The ST 53 catalogue separates the 927-5 family for ZG 150A, the 927-3K family for ZG 150K and the 927-3S family for ZG 150S. The shared 927 designation does not establish mechanical, software or electrical interchangeability.

Operating system and user-program memory

The operating-system EPROM associated with the 927 board is distinct from the machine's user program. Record the system-software revision and the machine program stored in RAM or EPROM separately. When reviewing S5 memory modules, establish each module's function, address-jumper configuration and position in the existing system as well as its capacity.

Memory models such as 6ES5 373-0AA21 and 6ES5 373-0AA41 may be encountered when investigating user memory and programming equipment. They must not be treated as unconditional substitutes for the 927 board's operating-system EPROM. Memory transfer requires the correct programmer, suitable adapter and a verified backup image.

System capacity and jumper checks

Siemens ST 53 specifies a maximum of 24 × 1024 program instructions of 16 bits each, 128 timers and 128 counters for the S5-150A/K system. The timer range is 0.01–9990 seconds and the counter range is 0–999. These are system specifications; they must not be interpreted as the standalone 927-5BA13 board's internal user-RAM capacity.

The manufacturer's jumper table covering the exact order code includes NAU/BAU, GEP, MEM for operating-system EPROM enable, and the ZYK test point. These are hardware control settings. Photograph the existing positions before removal and change them only against documentation covering the board revision and machine configuration.

Programming, connections and field signals

S5-150A programming access uses a suitable S5 interface board. When considering PG 511 boards such as 6ES5 511-5AA12 and 6ES5 511-5AA14, verify the revision and connection arrangement separately. Do not apply the front TTY-port arrangement or pin assignment of a CPU 942 to the 927 board.

Siemens' system diagram shows PG 670 and PG 675 programming access through a separate interface. Select S5 cables and connectors against the programmer, interface board and cable specification together. A connector fitting physically does not establish a correct electrical connection.

Sensor and control connections are handled through digital input modules, digital output modules and analog modules. 927-5BA13 is a central CPU board; PNP/NPN operation, 24 V DC ratings and analog measurement ranges are determined by the relevant peripheral module. Check the S5 rack and chassis arrangement and the board's mechanical location during installation.

Editor's Note

Begin with clear photographs of the complete label, EPROM markings and jumpers. Searching only for “927” can easily mix an S5-150A board with a 150K or 150S version.

Before removing the original board, record the order numbers of the 925 and 926 boards too. Processing duties are distributed across the assembly, so a replacement needs to be assessed with its companion boards.

Keep the machine-program backup separate from the operating-system EPROM image. Confirm what each backup contains before replacing an EPROM or erasing memory.

When a spare arrives, compare the exact revisions before copying jumper positions. Inspect sockets and contacts for looseness, corrosion or signs of previous modification as well.

Testing should cover correct programmer access, program comparison, fault information and machine response under safe conditions. The Siemens S5 maintenance information provides background; assess a used board against its own test record.

OtomasyonAVM resources

6ES5 927-5BA13 main page · Used Siemens S5 models · Siemens S5 technical information

Related topics

925-5AA12 central board · 926-5AA12 central board · 927-5BA12 · 927-3KA13 · 927-3SA11

These links support component identification and order-code comparison; they do not establish direct interchangeability.

Navigation

Siemens · Siemens S5 · SIMATIC S5 · Memory modules · Interface boards · Racks and chassis

External references

Siemens System 8 commissioning document – CPU 925/926/927 jumper table, page 5-14 – German PDF
Siemens ST 53 / 1985 – S5-130 and S5-150 catalogue, archive copy – German PDF