ST1RD2

Mitsubishi ST1RD2 Compact RTD Input Module

The ST1RD2 is a compact RTD (Resistance Temperature Detector) input module from Mitsubishi Electric’s MELSEC ST series, designed specifically for precise temperature sensing applications. This module supports 2 channels for RTD sensors, compatible with PT100 and PT1000 types. Packaged in a 1 module size, the ST1RD2 is ideal for temperature monitoring in industrial settings where space efficiency is important.

Technical Specifications

    Module Type: RTD input module
    Number of Channels: 2
    Supported Sensor Types: PT100, PT1000
    Temperature Range: Wide operational range suitable for diverse industrial environments (specific ranges depend on RTD sensor specifications)
    Module Size: Compact, occupying only 1 module width
    Certifications: CE certified for industrial compliance

Supported Software and Peripheral Devices

The ST1RD2 is compatible with Mitsubishi’s GX Configurator-ST software, facilitating easy configuration and integration within the MELSEC ST system. It seamlessly integrates with other MELSEC ST input/output modules, providing flexibility in complex automation setups. The module’s small size and compatibility with PT100 and PT1000 sensors make it adaptable for various temperature control and monitoring applications.

Recommendations and Commissioning Notes

When installing the ST1RD2, ensure the RTD sensors (PT100 or PT1000) are correctly calibrated for accurate temperature readings. Due to its compact design, the module can be easily integrated into systems with limited space, but proper wiring and insulation are essential for precise temperature measurements. Regular checks of sensor connections and calibration are recommended to maintain measurement accuracy and prevent signal drift over time.


>> Mitsubishi ST1RD2 User manual (pdf)

  ----------

+ Mitsubishi Automation Homepage

+ Mitsubishi Electric Contact (for Automation Mall)

+ About Mitsubishi Electric

Reminder: Mitsubishi ST1RD2 and other Mitsubishi PLC modules are available for sale at Otomasyon Mall. Please note that some of the devices are used products, so take this into consideration when purchasing. However, once products are out of stock, new ones will not be restocked. The information above is based on general knowledge and does not guarantee accuracy. For more detailed and precise information, it is recommended to refer to the relevant device’s user manual. 07.12.2012 

"Please note: The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please do not hesitate to share them with us."