Omron V7 fault codes 3

OH (Heatsink Overheat - Running):

    Check load size, V/f pattern setting, intake air temperature, cooling fan operation, and surrounding thermal sources.

OH9 (Motor Overheating - Running):

    Similar checks and actions as OH8.

RH (Externally-Mounting-Type Braking Resistor Overheat):

    Increase deceleration time and reduce regenerative load.

OL1 (Motor Overload):

    Check load size, V/f pattern setting, motor rated current, and ensure settings for motor protection and time constant are correct.

OL2 (Inverter Overload):

    Similar checks and actions as OL1, with additional checks for Inverter capacity.

OL3 (Overtorque Detection - Running):

    Similar checks and actions as OL3, with additional checks for operating conditions and load size.

PF (Main Circuit Voltage Fault):

    Check for open phase of input supply, momentary power loss, fluctuation in input supply voltage, and unbalanced line voltage.

LF (Output Open Phase):

    Check for disconnection in output cable, motor windings, and loose output terminal screws.