Omron 3G3JX VFD

The Omron SYSDRIVE JX Series VFD is an easy-to-use inverter for simple applications.
• Compact models with a wide range of capacity from 0.2 kW to 7.5 kW.
• Main circuit adopts upper/lower wiring as with contactor.
• Side-by-side mounting contributes to space saving.
• Built-in radio noise filter for three-phase type.
• Built-in RS-485 Modbus
DC injection braking, which starts at a frequency lower than that in deceleration via the STOP command, at a value set lower than that during operation, or via an external input. (Level and time settable.)

Protective functions including overcurrent, overvoltage, undervoltage, electronic thermal, temperature error, ground-fault overcurrent at power-on state, overload limit, incoming overvoltage, external trip, memory error, CPU error, USP trip, communication error, overvoltage protection during deceleration, momentary power interruption protection, emergency shutoff.
Input signal Multi-function input such as FW (forward), RV (reverse), CF1 to CF4 (multi-step speed), JG (jogging), DB (external DC injection braking), SET (2nd function), 2CH (2-step acceleration/deceleration), FRS (free run), EXT (external trip), USP (USP function), SFT (soft lock), AT (analog current input function selection), RS (reset), PTC (thermistor input), STA (3-wire startup), STP (3-wire stop), F/R (3-wire forward/reverse), PID (PID selection), PIDC (PID integral reset), UP (UP of UP/DWN function), DWN (DWN of UP/DDWN function), UDC (data clear of UP/DWN function), OPE (forced OPE mode), ADD (frequency addition), F-TM (forced terminal block), RDY (operation ready), SP-SET (special setting), EMR (emergency shutoff).
Output signal Multi-function output such as RUN (signal during operation), FA1 (frequency arrival signal 1), FA2 (frequency arrival signal 2), OL (overload warning signal), OD (PID excess deviation signal), AL (alarm signal), DC (analog input disconnection detection signal), FBV (PID FB status output), NDc (network error), LOG (logical operation result), LOC (light load signal).

Frequency monitor: Analog output (0 to 10 V DC, 1 mA max.)
Frequency/Current signals are selectable via the AM output terminal.
Relay output: The relay (SPDT contact) outputs signals corresponding to the multi-function output.
Other functions including AVR function, V/f characteristic selection, upper/lower limit, 16-step speeds, starting frequency adjustment, jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/bias adjustment, S-shape acceleration/deceleration, electronic thermal characteristics/level adjustment, retry function, simplified torque boost, trip monitor, soft lock function, frequency conversion display, USP function, 2nd control function, motor rotation speed UP/DOWN, overcurrent suppression function.

General specifications such as Ambient temperature, Ambient storage temperature, Humidity, Vibration, Location, Complies with UL, cUL, CE standards, and options like Noise filter, AC/DC reactors, regenerative braking unit and resistor, etc.