   oL1/oL2 (Motor/Inverter Overload):
+ Meaning: The motor or inverter is overloaded.
+ Possible Causes: The load is too heavy, acceleration/deceleration times, and cycle times are too short.
+ Corrective Actions: Check the load size and acceleration/deceleration times. Use the speed search function and adjust the settings. Increase the inverter capacity if necessary.

   oL3/oL4 (Over-Torque Detected 1/2):
+ Meaning: The current exceeded the set value for a certain period of time.
+ Possible Causes: Excessive torque in the mechanical system.
+ Corrective Actions: Ensure that the L6-02 and L6-03 settings are appropriate. Check the mechanical system and correct the cause of the excessive torque.

   UL3 (Insufficient Torque Detected 1/2):
+ Meaning: The current was lower than the set value for a certain period of time.
+ Possible Causes: Insufficient torque in the mechanical system.
+ Corrective Actions: Ensure that the L6-02 and L6-03 settings are appropriate. Check the mechanical system and correct the cause of the insufficient torque.

   oS (Overspeed):
+ Meaning: The speed exceeded the value set in F1-08 for longer than the time set in F1-09.
+ Possible Causes: Excessive acceleration/deceleration, the reference speed being too high.
+ Corrective Actions: Readjust the gain. Check the reference circuit and reference gain. Verify the F1-08 and F1-09 settings.

   PGo (PG Disconnection Detected):
+ Meaning: PG pulses were input while the inverter was providing a frequency output.
+ Possible Causes: Disconnection in the PG wiring, incorrect PG connection, no power supply to PG, motor brake being applied.
+ Corrective Actions: Fix any disconnection in the wiring. Correctly connect the PG. Ensure proper power supply to PG. Check for open circuits when the motor brake is applied.

   dEu (Excessive Speed Deviation):
+ Meaning: The speed deviation exceeded the value set in F1-10 for longer than the time set in F1-11.
+ Possible Causes: Heavy load, too short acceleration and deceleration times, load locking.
+ Corrective Actions: Reduce the load. Extend acceleration and deceleration times. Check the mechanical system. Verify the F1-10 and F1-11 settings. Check for open circuits when the motor brake is applied.

   CF (Control Error):
+ Meaning: During open-loop vector control, the torque limit was continuously reached for 3 seconds or longer during a deceleration stop.
+ Possible Causes: Inappropriate torque limit settings, inappropriate motor constant settings.
+ Corrective Actions: Check the torque limit settings. Verify the motor constant settings. Perform auto-tuning.

   FbL (PID Feedback Reference Loss):
+ Meaning: PID feedback reference loss was detected, and the PID feedback input was below the value set in b5-13 for longer than the time set in b5-14.
+ Possible Causes: Inappropriate b5-13 and b5-14 settings, incorrect wiring of the PID feedback circuit.
+ Corrective Actions: Check the b5-13 and b5-14 settings. Correct the wiring of the PID feedback circuit.

   EF0/EF3 (External Fault Input/External Fault from Communication Option Card):
+ Meaning: An "external fault" was input from a multifunction input terminal.
+ Possible Causes: External fault input.
+ Corrective Actions: Reset the external fault inputs on the multifunction inputs. Remove the cause of the external fault.

   EF8 (Zero-Servo Error):
+ Meaning: The rotational position moved during a zero-servo operation.
+ Possible Causes: Torque limit is too small, load torque is too large.
+ Corrective Actions: Increase the torque limit. Reduce the load torque. Check for signal noise.

   SEr (Exceeded Permissible Number of Speed Search Attempts):
+ Meaning: Speed search was repeated more times than the number set in b3-19.
+ Possible Causes: Inappropriate b3-17 and b3-18 settings.
+ Corrective Actions: Ensure that the b3-17 and b3-18 settings are appropriate.

   oPr (Digital Operator Connection Error):
+ Meaning: The connection to the Digital Operator was lost when a Run Command was received from the Digital Operator.
+ Possible Causes: Disconnection of the Digital Operator.
+ Corrective Actions: Check the connection to the Digital Operator.