Omron E7 fault codes

oC (Overcurrent)

   Meaning: The inverter's output current exceeded the detected overcurrent level.
   Possible Causes:
+ A short circuit or ground fault may have occurred (this could be due to damaged cables, motor burnout, or insulation wear).
+ The load may be too large, or the acceleration time may be too short.
+ A special motor or a motor too large for the inverter may be in use.
+ A magnetic switch may have been activated during operation.
   Corrective Actions: Resolve the cause and reset the error.

GF (Ground Fault)

   Meaning: A ground fault occurred at the inverter output, with up to approximately 50% of the inverter's rated output current.
   Possible Causes:
+ A ground fault may have occurred at the inverter output due to damaged cables, motor burnout, or insulation issues.
   Corrective Actions: Identify and correct the issue, then reset the error.

P_uF (Fuse Blown)

   Meaning: The fuse in the main circuit has blown.
   Possible Causes:
+ One of the IGBTs in the output failed, or a short circuit or ground fault occurred.
   Corrective Actions:
+ Check the motor and cables for short circuits or insulation failures.
+ Replace the inverter after the issue is resolved.

oU (Main Circuit Overvoltage)

   Meaning: The DC voltage in the main circuit exceeded the overvoltage detection level. (Approximately 410V for the 200V class, 820V for the 400V class).
   Possible Causes:
+ The acceleration time may be too short, or the regenerative energy from the motor may be too high.
+ The power supply voltage may be too high.
   Corrective Actions:
+ Increase the acceleration time or add a braking option.
+ Reduce the voltage to remain within the inverter’s limits.

u_u1 (Main Circuit Undervoltage)

   Meaning: The DC voltage in the main circuit dropped below the undervoltage detection level.
+ 200V class: Approximately 190V
+ 400V class: Approximately 380V
   Possible Causes:
+ A phase fault may have occurred in the input power supply.
+ A temporary power loss may have occurred.
+ The cable connections to the input power supply may be loose.
+ The voltage fluctuations in the input power supply may be too high.
+ A fault may have occurred in the inrush current prevention circuit.
   Corrective Actions: Correct the issue and reset the error.

u_u2 (Control Power Fault)

   Meaning: A voltage drop occurred in the control power supply.
   Possible Causes: None specified.
   Corrective Actions:
+ Try turning the power supply off and on again.
+ If the error persists, replace the inverter.

u_u3 (Inrush Current Prevention Circuit Fault)

   Meaning: The inrush current prevention circuit overheated.
   Possible Causes:
+ The magnetic contactor (MC) in the main circuit failed.
+ The MC's coil may have burned out.
+ A phase fault may have occurred in the input power supply.
   Corrective Actions:
+ Try turning the power supply off and on again.
+ If the error persists, replace the inverter.