Omron 3G3IV fault codes 2

PGo (PG Disconnection Detected):
- Reasons: PG pulses were inputted while the inverter was providing a frequency output.
- Solutions: Correct the disconnected/broken wiring. Connect the PG correctly. Supply power correctly to the PG. Check the open circuit while using the motor brake.

dEu (Over Speed Deviation):
- Reasons: Speed deviation exceeded the value set in F1-11 for longer than the value set in F1-10.
- Solutions: Reduce the load. Extend acceleration and deceleration times. Check the mechanical system. Check F1-10 and F1-11 settings. Check the open circuit while using the motor brake.

CF (Control Error):
- Reasons: During open-loop vector control, torque limit was continuously reached for 3 seconds or longer at a deceleration stop.
- Solutions: Check the torque limit settings. Check the motor constants settings. Perform auto-tuning.

FbL (PID Feedback Reference Loss):
- Reasons: PID feedback reference loss detected, and the PID feedback input was lower than the value set in b5-14 for longer than the value set in b5-13.
- Solutions: Check b5-13 and b5-14 settings. Correct the wiring of the PID feedback circuit.

EF0/EF3 (External Fault Input/External Fault from Communication Option Card):
- Reasons: "External fault" input was made from a multifunctional input terminal.
- Solutions: Reset the external fault inputs in multifunctional inputs. Remove the cause of the external fault.

EF8 (Zero-Servo Error):
- Reasons: Rotation position moved during zero-servo operation.
- Solutions: Increase the torque limit. Reduce the load torque. Check the signal noise.

SEr (Speed Search Attempts Exceeded):
- Reasons: Speed search exceeded the number set in b3-19.
- Solutions: Make sure b3-17 and b3-18 settings are correct.

oPr (Digital Operator Connection Error):
- Reasons: Connection to the Digital Operator was lost when a Run Command was received from the Digital Operator for operation.
- Solutions: Check the connection to the Digital Operator.

CE/bUS (MEMOBUS Communication Error/Option Communication Error):
- Reasons: A communication error was detected during a Run Command or setting a frequency reference from an Option Communication Card.
- Solutions: Check the communication devices and signals.

ES (SI-T Monitoring Error):
- Reasons: Consistency error in received control data, synchronization error between the main controller and the Inverter for control data.
- Solutions: Check communication timing, e.g., communication cycle.

E-10 (SI-F/G Option Card CPU Fault):
- Reasons: SI-F/G Option Card operation failed.
- Solutions: Check or replace the option card.

CPF00-CPF10 (Digital Operator Connection Error, Inverter Control Circuit Error, Digital Operator Communication Error 1/2, Base Block Circuit Error, EEPROM Error, CPU Internal/External A/D Converter Error, Option Card Connection Error, ASIC Internal RAM Error, Monitoring Timer Error, CPU-ASIC Mutual Diagnosis Error, ASIC Version Error):
- Reasons: Incorrect Digital Operator connection, faulty inverter control circuit, communication failure with the Digital Operator, faulty base block circuit, faulty EEPROM, faulty CPU internal/external A/D converter, faulty option card connection, faulty ASIC internal RAM, faulty monitoring timer, faulty CPU-ASIC mutual diagnosis, faulty ASIC version.
- Solutions: Turn the power supply on and off. Replace the inverter or option card. Check the Digital Operator connection and reconnect it. Initialize the fixed settings.

CPF20-CPF23 (Communication Option Card A/D Converter Error, Communication Option Card Self Diagnosis Error, Communication Option Card Model Code Error, Communication Option Card DPRAM Error):
- Reasons: Faulty communication option card, faulty A/D converter, model code error, DPRAM error.