NP1PU-048E and NP1PU-256E: SPH3000 CPUs

NP1PU-048E and NP1PU-256E are CPU modules in Fuji’s MICREX-SX SPH3000 family. A CPU does not replace a field-input or output card; signals connect through separate Fuji PLC I/O modules. Fuji’s table lists 49,152 program steps for 048E and 262,144 program steps for 256E. The suffix matters when sizing program memory.

Speed and connections

Fuji quotes 9 ns or more per basic sequence instruction for SPH3000. That measures one instruction, not the complete program cycle with I/O and communications. The table lists USB and Ethernet options for these CPUs. Check the cabinet drawing and configuration to learn which port carries programming traffic and which serves the machine network.

A shared NP1PU prefix is not enough

NP1PU1 codes and SPH3300 have separate CPU entries. Do not replace a 048E or 256E using the NP1PU letters alone. Compare project backup, memory use, network settings and installed rack modules. Engineering tools sit in Fuji PLC software and manual titles in CPU documents.

The modular system context is explained under MICREX-SX SPH.

Fuji’s table gives these SPH3000 CPUs approximately five years of battery backup at 25 °C and a built-in flash option for saving the application program. Replacing a battery and confirming a recoverable project are different tasks. Check both on a spare CPU that has been stored for a long time.