invt Servo Fault Code DA180

INVT DA180 Servo Drive Fault and Warning Codes

INVT DA180 servo drive fault and warning codes help identify problems related to the power supply, servo motor, encoder feedback, communication, drive power stage or mechanical load. Correctly identifying the code displayed on the drive panel is the first step in troubleshooting the system.

The following list contains the main warning (AL) and error (Er) codes used by the DA180 series. Use the Read More >> links beside each code to open the corresponding detailed DA180 troubleshooting page.

INVT DA180 Warning Codes

AL-LT1 - Forward travel limit warning (PSL terminal disconnected) (Read More >>)

AL-LT2 - Reverse travel limit warning (RVL terminal disconnected) (Read More >>)

AL-EST - Emergency stop warning (EMG terminal disconnected) (Read More >>)

AL-Pof - Main circuit low-voltage warning (Read More >>)

AL-cTE - Communication abnormality warning (when Pc.26=1) (Read More >>)

INVT DA180 Error Codes

Er-EEP - EEPROM error or memory corruption (Read More >>)

Er-Ec1 - Encoder disconnection error 1 (Read More >>)

Er-Ec2 - Encoder phase wiring or cable error 2 (Read More >>)

Er-iTE - Current sensor or current detection circuit error (Read More >>)

Er-oc1 - Hardware overcurrent error (Read More >>)

Er-oc2 - Ground short-circuit error (Read More >>)

Er-ou - Overvoltage error (Read More >>)

Er-uu - Main DC bus undervoltage error (Read More >>)

Er-oL - Overload error (Read More >>)

Er-LnE - Power line or phase abnormality (Read More >>)

Er-oS - Overspeed error (Read More >>)

Er-oH1 - Servo drive / IGBT overtemperature error (Read More >>)

Er-oE - Excessive pulse or position deviation error (Read More >>)

Er-cTE - Communication timeout or excessive communication error rate (Read More >>)

Er-oT - EEPROM read/write timeout error (Read More >>)

Er-bcE - Brake resistor overload error (Read More >>)

Er-iPo - IPM module current detection abnormality (Read More >>)

Er-dP - Power supply phase-loss error (Read More >>)

Er-INE - Inertia identification error (Read More >>)

Er-DrE - Motor parameter mismatch error (Read More >>)

Checks for INVT DA180 Servo Faults

When a DA180 servo fault occurs, do not rely only on resetting the alarm. Check the power supply, servo motor connections, encoder cable, motor cable, mechanical load, braking resistor and communication wiring according to the displayed code.

For power-stage and load-related faults such as Er-oc1, Er-oc2, Er-ou, Er-oL and Er-oH1, the cause should be identified before repeatedly restarting the servo drive.

For Er-Ec1 and Er-Ec2, check the encoder connector, cable condition and motor-drive compatibility. For AL-cTE and Er-cTE, inspect the communication wiring and related communication settings.