Inovance H1U PLC User Manuals

The Inovance H1U is a compact PLC family developed for small and medium-sized machine automation. It combines the CPU, power supply and built-in I/O in a single controller while providing high-speed counting, pulse-output and serial communication functions in addition to conventional PLC logic.

H1U Hardware and Communication

The H1U-XP platform provides high-speed inputs of up to 60 kHz and, on suitable transistor-output models, pulse outputs of up to 100 kHz. These functions can be used for encoder feedback, high-speed counting and basic positioning applications.

Built-in communication includes RS422/RS485, Modbus RTU and Mini-USB. With an H1U-CAN-BD option board, compatible remote I/O can also be connected through Inovance's CANlink network.

The H1U does not use conventional side-mounted local I/O expansion. Instead, the platform uses BD function boards and CANlink remote expansion. Typical options include H1U-232-BD for RS232 communication, H1U-4A-BD for analog I/O and H1U-CAN-BD for CAN/CANlink functions.

See the Inovance PLC modules and options and Inovance expansion systems pages for related hardware.

Programming the H1U

H1U PLCs can be programmed, downloaded and monitored using AutoShop. The H1U programming architecture supports Ladder Diagram (LD), Instruction List (IL) and Sequential Function Chart (SFC) programming methods.

AutoShop and other engineering tools are available from the Inovance programming software section.

A Note on H1U Program Capacity

Different revisions of official Inovance H1U documentation specify different program capacities. Some earlier documentation lists 8K steps, while later H1U-XP product-selection documentation specifies 16K steps.

For maintenance, replacement or program work on an existing machine, always use the complete PLC part number and the documentation revision applicable to the installed controller.

H1U Technical Documentation

This section provides access to available Inovance H1U PLC manuals and technical documentation. Select the manual according to the exact PLC model, option board and hardware revision installed in the machine.

Before replacing or modifying an H1U controller, check the complete CPU model, MR or MT output type, installed BD board, PLC program and any CANlink remote I/O modules.

H1U Legacy Product Status

Inovance currently lists the H1U as a legacy PLC platform. For new machine projects, a current Inovance PLC family should therefore be considered. H1U documentation, AutoShop software and expansion information nevertheless remain important for maintenance, spare-part identification and service of existing machines.