IC693CBL319

General Function of the Cables IC693CBL319 :

These cables, such as the IC693CBL311, IC693CBL319, and IC693CBL320, are used to connect Power Mate APM Modules (IC693APU301 and IC693APU302) to machines and drives. Each APM module has two 24-pin male connectors on the front panel, and two cables are required for connecting the module to the drive and machine. These cables carry data and signals between the module and the terminal block.
IC693CBL319:

    A 3 feet (1 meter) long APM I/O cable that connects a 24-pin connector on the module to the terminal block.
    Two cables are required per APM module.

IC693CBL320:

    Similar to the IC693CBL319, but with a key difference: the drain shield wire is brought outside the connector instead of being connected to pin B12. This design improves the module’s noise immunity.
    It is also 3 feet (1 meter) long and is used with APM modules.
    Two cables are required per module.

Cable Structure and Connections:

These cables consist of a 24-pin I/O connector, the cable itself, and a 25-pin D-type terminal block connector. Both ends of the cable are designed to provide a pin-to-pin connection. For example:

    I/O connector pin A1 is connected through wire pair 1 to pin 12 on the 25-pin connector.
    I/O connector pin B1 is connected through wire pair 1 to pin 11 on the 25-pin connector.
    This pattern continues for all pins according to the table.

 It lists the pin numbers on the 24-pin I/O connector and their corresponding 25-pin terminal block connections, as well as the wire pair used for each connection.
Usage with APM Modules:

These cables are used to connect Power Mate APM modules to drives and machines. Typically, a short I/O Interface cable connects the module to a terminal block. The length of the cable can be shortened to meet installation requirements. For further details on APM terminal blocks, refer to manual GFK-0840 (standard mode) or GFK-0781 (follower mode).

This summary provides a better understanding of the cabling and connection requirements for your APM modules. Proper connection of these cables is essential for reliable system operation.



IC693CBL319 User manual (pdf)

>> Ge fanuc 90-30 User manual (pdf)

++ Other 90-30 PLC modules

----------

+ Ge-Fanuc 2 Homepage

+ Ge-Fanuc Contact (for Automation Mall)

+ About Ge-Fanuc

Reminder: IC693CBL319 and other Ge-Fanuc modules are available for sale at Otomasyon Mall. Please note that some of the devices are used products, so take this into consideration when purchasing. However, once products are out of stock, new ones will not be restocked. The information above is based on general knowledge and does not guarantee accuracy. For more detailed and precise information, it is recommended to refer to the relevant device’s user manual. 06.03.2013 

"Please note: The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please do not hesitate to share them with us."   

Your shopping cart is empty!