IC693CBL301 I/O Bus Expansion Cable Overview for Electricians
What Does This Cable Do? The IC693CBL301 is a 2-meter (6-foot) I/O bus expansion cable, part of a series of prefabricated cables used to connect a Serial Bus Transmitter Module (IC695LRE001) to a Serial Expansion Backplane (IC694/693CHS392 or IC694/693CHS398). This cable helps expand the system by linking multiple backplanes together, providing a path for data transfer.
Like other cables in this series, it comes with 100% continuous shielding, meaning it prevents electrical noise from interfering with the signals. The shielding is braided and grounded to the metal shell of the connectors, making it highly effective at blocking noise.
Types of Cables: Here’s how the different cables in this family vary:
IC693CBL300: 1 meter (3 feet)
IC693CBL301: 2 meters (6 feet)
IC693CBL302: 15 meters (50 feet)
Other models like IC693CBL312, 313, and 314 vary mainly by length but serve the same purpose.
These cables come in either two-connector or three-connector (“wye”) formats:
Two-connector cables (e.g., IC693CBL302) connect only one backplane and the CPU baseplate.
Three-connector cables (e.g., IC693CBL301) allow for daisy-chaining up to seven backplanes.
Important Installation Details:
If you’re linking multiple backplanes, the last one must be terminated using a Terminator Plug (IC693ACC307), or you may experience system instability.
The maximum allowable total cable length is 50 feet (15 meters). Exceeding this length could lead to signal loss or noise issues.
Inside the Cable: Each cable carries multiple signals:
DIODT: I/O Serial Data
DIOCLK: I/O Serial Clock
DRSEL: Remote Select Signal
DRMRUN: Remote Run Signal
Each signal has positive and negative wires (e.g., pin 2 connects to pin 2, pin 3 to pin 3, etc.). All cables must be connected point-to-point to ensure proper signal transmission.
Building Custom Cables: For custom-length cables, achieving the best noise immunity requires the use of a metalized connector cover that makes solid contact with the cable’s shield. It’s not enough just to solder the drain wire; the shielding must be continuous from end to end, including at the terminations.
Steps for building a shielded cable:
Strip 5/8 inch of insulation to expose the shield.
Slide a split-ring ferrule over the cable insulation.
Fold the shield back over the cable and ferrule.
Securely clamp the metal hood onto the folded shield.
Test for continuity using an ohmmeter to ensure the shield is properly connected.
Summary:
The IC693CBL301 cable is essential for linking expansion backplanes to a main backplane or CPU in your system.
It comes with effective shielding to prevent interference and ensure stable signal transmission.
For proper functioning, the last backplane must be terminated, and total cable length must not exceed 50 feet.
These cables are straightforward to install but require attention to grounding and shielding for optimal performance.