General Electric AF-6 Fault index
Hi everyone,
- Error Code 1: 10 Volts Low - Control card voltage is below 10 V from terminal 50. More info (continue >)
- Error Code 2: Live Zero Error - Appears if Live Zero Timeout Function is programmed. More info (continue >)
- Error Code 4: Mains Phase Loss - A phase is missing on the supply side, or the mains voltage imbalance is too high. More info (continue >)
- Error Code 5: DC Link Voltage High - Intermediate circuit voltage (DC) is above the high voltage warning limit. More info (continue >)
- Error Code 6: DC Link Voltage Low - Intermediate circuit voltage (DC) is below the low voltage warning limit. More info (continue >)
- Error Code 7: DC Over Voltage - If intermediate circuit voltage exceeds the limit, the drive stops after a time. More info (continue >)
- Error Code 8: DC Under Voltage - If intermediate circuit voltage (DC link) falls below the under voltage limit, the drive stops. More info (continue >)
- Error Code 9: Inverter Overloaded - Drive may cut out due to overload. More info (continue >)
- Error Code 10: Motor Overload Temperature - Electronic thermal protection indicates the motor is too hot. More info (continue >)
- Error Code 11: Motor Thermistor Over Temperature - Motor thermistor has reached excessive temperature levels. More info (continue >)
- Error Code 12: Torque Limit - The set torque limit has been exceeded. More info (continue >)
- Error Code 13: Over Current - Inverter's peak current limit (approximately 200% of rated current) has been exceeded. More info (continue >)
- Error Code 14: Earth Fault - There is a ground leakage in one of the output phases. More info (continue >)
- Error Code 15: Hardware Mismatch - An installed option card is not compatible with the current control card hardware or software. More info (continue >)
- Error Code 16: Short Circuit - There is short-circuiting in the motor or motor wiring. More info (continue >)
- Error Code 17: Control Word Timeout - No communication to the drive. More info (continue >)
- Error Code 18: Start Failed - Motor speed did not exceed the allowed start maximum speed during startup. More info (continue >)
- Error Code 23: Internal Fan Fault - Checks if the fan is operational. More info (continue >)
- Error Code 24: External Fan Fault - Checks if the fan is operational. More info (continue >)
- Error Code 29: Heatsink Temp High - Maximum heatsink temperature has been exceeded. More info (continue >)
- Error Code 30: Motor Phase U Missing - Motor phase U is missing between the drive and the motor. More info (continue >)
- Error Code 31: Motor Phase V Missing - Motor phase V is missing between the drive and the motor. More info (continue >)
- Error Code 32: Motor Phase W Missing - Motor phase W is missing between the drive and the motor. More info (continue >)
- Error Code 33: Inrush Fault - Too many power-ups within a short time period. More info (continue >)
- Error Code 34: Communication Fault - Problem with the network on the communication option card. More info (continue >)
- Error Code 36: Mains Failure - The supply voltage to the drive has been lost. More info (continue >)
- Error Code 38: Internal Fault - An internal fault has occurred. More info (continue >)
- Error Code 39: Heatsink Sensor - No feedback from the heatsink temperature sensor. More info (continue >)
- Error Code 45: Earth Fault 2 - Ground fault occurred on startup. More info (continue >)
- Error Code 46: Power Card Supply - The supply on the power card is out of range. More info (continue >)
- Error Code 47: 24V Supply Low - 24 V DC is measured on the control card. More info (continue >)
- Error Code 48: 1.8V Supply Low - 1.8V DC supply on the control card is outside of allowable limits. More info (continue >)
- Error Code 49: Speed Limit - Speed is outside the specified range. More info (continue >)
- Error Code 50: Auto Tune Calibration Failed - Auto tune calibration was unsuccessful. More info (continue >)
- Error Code 51: Auto Tune Check Unom and Inom - Settings for motor voltage, current, and power are incorrect. More info (continue >)
- Error Code 52: Auto Tune Low Inom - Motor current is too low. More info (continue >)
- Error Code 53: Auto Tune Motor Too Big - The motor is too large for the auto tune process. More info (continue >)
- Error Code 54: Auto Tune Motor Too Small - The motor is too small for the auto tune process. More info (continue >)
- Error Code 55: Auto Tune Parameter Out of Range - Parameter values of the motor are outside the acceptable range. More info (continue >)
- Error Code 56: Auto Tune Interrupted by User - Auto tune has been interrupted by the user. More info (continue >)
- Error Code 57: Auto Tune Timeout - Auto tune has timed out. More info (continue >)
- Error Code 58: Auto Tune Internal Fault - An internal fault has occurred during auto tune. More info (continue >)
- Error Code 59: Current Limit - The current is higher than the value set in the current limit parameter. More info (continue >)
- Error Code 60: External Interlock - A fault condition external to the drive has commanded the drive to stop. More info (continue >)
- Error Code 62: Output Frequency at Maximum Limit - The output frequency has reached the maximum limit set. More info (continue >)
- Error Code 65: Control Card Over Temperature - The cutout temperature of the control card is reached. More info (continue >)
- Error Code 66: Heatsink Temperature Low - The drive is too cold to operate. More info (continue >)
- Error Code 67: Option Module Configuration Changed - One or more options have been added or removed since the last power down. More info (continue >)
- Error Code 69: Power Card Temperature - Temperature sensor on the power card is either too hot or too cold. More info (continue >)
- Error Code 70: Illegal Drive Configuration - The control card and power card are incompatible. More info (continue >)
- Error Code 80: Unit Restored to Factory Settings - Parameter settings are restored to factory settings after a manual reset. More info (continue >)
- Error Code 92: No Flow - No flow condition detected in the system. More info (continue >)
- Error Code 93: Dry Pump - No flow condition in the system with the drive operating at high speed may indicate a dry pump. More info (continue >)
- Error Code 94: End of Curve - Feedback is lower than the set point, which may indicate leakage in the system. More info (continue >)
- Error Code 95: Broken Belt - Torque is below the no-load torque level set, indicating a broken belt. More info (continue >)
- Error Code 96: Start Delayed - Motor start has been delayed due to short-cycle protection. More info (continue >)
- Error Code 97: Stop Delayed - Stopping the motor has been delayed due to short-cycle protection. More info (continue >)
- Error Code 98: Clock Fault - Time is not set or the RTC clock has failed. More info (continue >)
- Error Code 200: Fire Mode - Indicates the drive is operating in fire mode. More info (continue >)
- Error Code 201: Fire Mode was Active - Indicates the drive had entered fire mode. More info (continue >)
- Error Code 202: Fire Mode Limits Exceeded - Operating in fire mode, one or more alarm conditions have been ignored which would normally stop the unit. More info (continue >)
- Error Code 203: Missing Motor - An under-load condition was detected with a drive operating multi-motors. More info (continue >)
- Error Code 204: Locked Rotor - An overload condition was detected with a drive operating multi-motors. More info (continue >)
- Error Code 250: New Spare Part - A component in the drive has been replaced. More info (continue >)
- Error Code 251: New Type Code - The power card or other components have been replaced and the type code changed. More info (continue >)