4 Digit Gemo DS207 Counter

- Gemo control products have been sold on our website since 2013.

We have listed the most important and most frequently asked output type features about DS 207 counter below.

>> After the counting is finished, the display value decreases/increases until the reset signal is given and if OUT is not a single pulse, it remains in the “ON” position.
+ After the counting is finished, the display value remains constant. OUT remains “ON” until the reset signal is given.
+ After the counting is finished, the display value decreases/increases until the reset signal is given.
+ After the counting is finished, the display remains constant until the end of the OUT single pulse time. Count value becomes 'OFF'/reset at the end of OUT single pulse output.

++ After the counting is finished, the count value is reset, but the display remains constant until the end of the OUT single pulse time.

+ OUT is ON when the count value is equal to Preset. If the time when the count value is equal to Preset is too short, the Relay can be OFF without being ON. In this case, since SSR OUT is faster than the relay, it may be more convenient to use.
+ OUT is ON if the count value is greater than or equal to Preset. Normally closed contact of the Relay can be used for the case where the count value is less than Preset.
+ After the counting is finished, the display value remains constant. OUT remains “ON” until the reset signal is given. if not a single blow
+ After the counting is finished, the display value is reset.

- Counting Input: 2 (max. 7500 Hz, 5-30V)
- 2x4 digits, single set, single output forward/back counter, Forward/down counting with phase different input, Password protected
- Supply Voltage: 100..240VAC, 50-60Hz or 24Vac/dc (optional)

    If the Supply Voltage 24 V AC/dc is required, it must be specified with the order.

- Possibility to select 7 types of input / 9 types of output, OFFSET addition feature
- Sensor: PNP/NPN proximity switch - Encoder with NPN/PNP/Totem-pole output
- RESET possibility from the panel
- Counting Frequency: 20, 500, 2500, 7500Hz programmable
- Output contact; continuous output or 0.1..999.9 sec
- NPN Selection: If “npn select” input is short-circuited to “+12V” input, CP1 and CP2 inputs become NPN.
- Selectable counting frequency: Calibration multiplier selectable from 0.001 to 9.999
- Reset Input: 10ms (min), Positive Input (PNP Input) (5..30V)
- Possibility to monitor the preset value on the display
- Sensor Supply Exit. : 12VDC, 50mA max. (unregulated)
- Possibility to load the last count value at the time of power cut (it can keep the count value in its memory when the power is cut). Ds207 prices also show a difference.

- Magnetic compatibility: It can work in the same panel with internal insulation, motor speed control driver, inverter and materials that may be a source of interference.

- Gemo DS207 User manual (pdf)

- Gemo Home Page -

---------

Write a review

Note: HTML is not translated!
    Bad           Good

Gemo DS207 Counter

  • 370.00USD

  • Ex Tax: 370.00USD