Ge VAT300 fault codes 3

Hi everyone,

    Overheat (UOH.n)
- Description: Overheating detected, possibly due to cooling fan trouble, high ambient temperature, or clogged vent/heatsink.
- Cause: Inadequate cooling or high ambient temperature.
+ Solution: Replace the cooling fan if necessary, lower the ambient temperature, and clean the vent/heatsink.

    Overspeed (SP-1)
- Description: Motor rotation count exceeded the overspeed setting value.
- Cause: Excessive motor speed.
+ Solution: Adjust the ASR response, increase the acceleration time setting, or change the speed setting gradually.

    Speed Detection Error (SP-2)
- Description: Motor rotation speed fluctuation ratio exceeded the error level setting value.
- Cause: Speed detection error.
+ Solution: Check the encoder wiring.

    Speed Deviation Error (SP-3)
- Description: Difference between the motor rotation speed command value and detected value exceeds the error detection setting value.
- Cause: Speed deviation error.
+ Solution: Check the encoder wiring and adjust the speed command and S-pattern characteristics setting.

    Reverse Run Detection Error (SP-4)
- Description: Motor rotated in the reverse direction of the speed command and exceeded the error detection setting value.
- Cause: Reverse run error.
+ Solution: Check whether the motor ran in reverse due to the load and check the ASR torque limiter setting values.

    Encoder Initialization Error 1 (SP-5)
- Description: Encoder initialization error occurred during PM motor control.
- Cause: Encoder signal abnormality.
+ Solution: Check the encoder selection and wiring.

    Encoder Initialization Error 2 (SP-6)
- Description: Encoder initialization error occurred during PM motor control.
- Cause: Encoder signal abnormality.
+ Solution: Check the encoder wiring and improve the installation environment regarding noise.

    Fuse Blown (FUSE)
- Description: Main circuit fuse is disconnected.
- Cause: Wiring issue, foreign debris, short-circuit, or ground fault.
+ Solution: Check the main circuit input/output wiring and replace the fuse if blown.

    Parallel Unit Signal Cutoff (BPFLT)
- Description: Connection signal was disconnected when using a parallel machine.
- Cause: Wiring or connector issue.
+ Solution: Check the wiring and connector.

    Automatic Tuning Abnormal Completion (TT-n)
- Description: Automatic tuning completed abnormally.
- Cause: Motor may not be connected correctly, or parameters may not be set correctly.
+ Solution: Check the connection, parameter settings, and separate the load and machine if necessary.

    Equipment Load (OL-1)
- Description: VAT300 may have overloaded.
- Cause: Excessive load.
+ Solution: Reduce the load or increase the inverter capacity.

    DBR Overload (OL-2)
- Description: The regenerative power may be excessive.
- Cause: Excessive regenerative power.
+ Solution: Increase the deceleration time and reduce the regenerative power.

    Motor Overload (OL-3)
- Description: The motor may have overloaded.
- Cause: Excessive load on the motor.
+ Solution: Reduce the load or increase the motor and inverter capacity.

    Grounding (GRD.n)
- Description: A ground fault may have occurred in the power cable or motor.
- Cause: Ground fault.
+ Solution: Restore the grounded point and improve the installation environment regarding noise.

    I/O Error (IO-1, IO-2, IO-3, IO-4, IO-B)
- Description: I/O errors related to gate turn-off circuit, A/D converter, current detection, retry time-out, and PID settings.
- Cause: External noise, control circuit fault, or incorrect settings.
+ Solution: Look for the noise source and remove the cause. Check the control circuit and settings.

    External Brake Errors (IO-C, IO-D, IO-E)
- Description: Errors related to external brake IDET, RUN, and answer signals.
- Cause: Incorrect settings or motor wiring connections.
+ Solution: Check the settings and motor wiring connections.

    CPU Error (CPU-n)

- Description: Unit malfunctioning due to external noise or control circuit fault.
- Cause: External noise or control circuit fault.
+ Solution: Look for the noise source and remove the cause. Check the control circuit. Power cycle the unit.

    E2PROM Data Error (DER)
- Description: Incorrect parameter setting value.
- Cause: Incorrect parameter setting.
+ Solution: Correct the parameter setting value.

    Verify Check Data Error (EP.ERR.)
- Description: Error occurred during verify check in the parameter copy function using the operation panel.
- Cause: Verification error.
+ Solution: Execute the parameter copy function again.

    Input Phase Failure (PHL1)
- Description: Phase failure in the AC input power supply.
- Cause: Phase failure or high load pulsation.
+ Solution: Investigate the AC input power supply and eliminate the phase failure. Check the AC input wire tightening.

    Output Phase Failure (PHL2)
- Description: Primary coil of the motor may not be correct.
- Cause: Motor or wiring issue.
+ Solution: Check the motor and wire tightening state.

    MC Error (MC-1)
- Description: Pre-charge magnetic contactors may not be working properly.
- Cause: Magnetic contactor failure.
+ Solution: Turn the power off and check the magnetic contactors and auxiliary contacts.

+ Ge VAT300 User manuals >

+ Ge VAT300 Fault Codes 1 >

+ Ge VAT300 Fault Codes 2 >

+ Ge VAT300 Fault Codes 3 >


+ General Electric 2. Main page >

+ VFD Homepage > 


-

"* The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please do not hesitate to share them with us."  03.01.2013