Hi everybody,

This drive appears to be a versatile and user-friendly solution for a variety of fan, pump, compressor, and blower applications, with features like motor auto-tuning, energy savings mode, and energy monitoring to help save time and energy. The drive is available in a range of voltage options, and with various communication and mounting options, it can be easily integrated into building automation systems or used in harsh environments if needed.

The drive's LCD Keypad Display and Quick Menu, Application Macros, and intuitive Keypad make it easy to use, and the Plenum rating allows it to be mounted inside air handling ducts. Overall, the AF-600FP seems to be a well-rounded product that offers a number of useful features and options for customers in the HVAC, compressor, and pump industries.

This drive has a number of specifications and features that make it well-suited for use in a variety of environments and applications. The drive has several different enclosure options available, including IP20 Chassis, IP00 Chassis, IP21/NEMA 1, IP55/NEMA 12, and IP54/NEMA 12, which allows for installation in a variety of locations. The drive is also Plenum rated, making it suitable for installation inside air handling ducts and plenums.

The drive has a storage temperature range of -25°C to 65°C, and an ambient temperature range of -10°C to 50°C, with an average maximum of 45°C. The drive is designed to operate in an ambient humidity range of 5% to 95% RH, and is capable of withstanding 1.0g of vibration. It is cooled by a fan and has adjustable fan control options. The drive meets a number of standard approvals, including CE, UL, cUL, and C-Tick, and is suitable for use on a circuit capable of delivering up to 100,000 rms symmetrical amperes for 208/230V and 460V.

The drive has a range of input power supply options, including 200-240 Vac, 380-480 Vac, and 525-600 Vac, with a maximum voltage imbalance of 3% and a true power factor of greater than 0.9. The drive has built-in DC link reactors and RFI filters to reduce noise generated by the drive. The output frequency range is 0-1000 Hz, with accel/decel times ranging from 1-3600 seconds, and control is performed using sinusoidal PWM control. Overall, the specifications and features of the AF-600FP Fan and Pump Drive suggest that it is a well-rounded and capable solution for a variety of fan, pump, compressor, and blower applications.

These are various features and settings available on a variable frequency drive (VFD).

Starting Torque: The VFD has a 110% starting torque capability for a duration of 1 minute, which is useful for starting heavy loads.
Carrier Frequency: The VFD allows you to select the carrier frequency, or motor noise, from a range of options, from 1 to 16 kHz.
Torque Boost: The torque boost setting compensates for voltage changes in relation to the load at low speeds, and can be set from 0 to 300%.
Acceleration/Deceleration Time: The VFD allows you to set the acceleration and deceleration time between 0.01 and 3600 seconds. The acceleration and deceleration patterns can be selected from linear or S-curve.
Data Protection: The VFD has password protection for the quick menu or main menu, with a range of 0-9999.
Pattern Operation: The VFD has built-in logic controller sequencer that allows for pattern operation settings.
Jump Frequency Control: The VFD allows you to set jump frequencies to avoid mechanical vibrations.
Slip Compensation: The VFD can maintain the motor's speed with fluctuations in the load.
Torque Limit Control: The VFD allows you to control the output torque within a range of 0.0 to 110% with steps of 0.1.
Preset Speeds: The VFD has 8 programmable preset speeds that can be selected by 3 digital inputs.
Built-In Communications: The VFD has various built-in communication options such as RS-485, Modbus RTU, Metasys N2, or Apogee FLN P1.
Trim Reference Setting: The VFD allows for speed reference offset via a potentiometer, voltage input, or current input.
DC Injection Braking: The VFD has a DC injection braking feature that can start at a frequency of 0.0-1000 Hz and has a braking time of 0.0-60.0 seconds, with a braking level of 0-100% of rated current.
Jogging Operation: The VFD can perform jogging operations via an on-key or digital input (Fwd or Rev).
Auto-Restart: The VFD can restart after a power failure without stopping.
Energy Savings: The VFD can control the output voltage to minimize motor losses during constant speed operation.
Start Mode Function: The VFD has a start mode function that smoothly catches a spinning motor.
Fire Override Mode: The VFD has a fire override mode that overrides the drive's protective features and keeps the motor running.
Pump Cascade Controller: The VFD has a pump cascade controller that distributes running hours evenly over up to 4 pumps.
Sleep Mode: The VFD has a sleep mode that detects low or no flow conditions and adjusts the output.
Dry Pump Detection: The VFD can detect pump operations and set off alarms, shut off, or perform other programmed actions.
Belt Monitoring: The VFD can detect the relationship between current and speed to recognize a broken belt.
Real Time Clock: The VFD has a real-time clock with programmable timed actions.
Logic Controller: The VFD has a logic controller (LC) sequencer with programmable events, comparators, timers, logic rules, and action states.
Process Controller: The VFD has a process controller (PID) with 4 auto-tune PID controllers built-in, and various options for process control, such as normal or inverse, anti-windup.

+ Ge AF-6 Brochure   (pdf) 

+ Ge AF-6 Catalogue   (pdf) 

+ Ge AF-6 Drive Operating Instructions   (pdf) 

+ Ge AF-6 Montage manual   (pdf) 

+ Ge AF-650 User manual   (pdf) 

+ Ge FUJI Af300 user manual   (pdf) 


+ GE- AF-600 FP User Manuals >>

+ Ge AF-6 (600,650..) Fault index >>

+ Ge AF-6 (600,650..) Fault Codes 1 >>

+ Ge AF-6 (600,650..) Fault Codes 2 >>

+ Ge AF-6 (600,650..) Fault Codes 3 >>

+ Ge AF-6 (600,650..) Fault Codes 4 >>


+ General Electric 2. Main page >

+ VFD Homepage > 


-

"* The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please do not hesitate to share them with us."  29.01.2013   


Refine Search