GE- AF-600 FP fault index

Hi everyone,
General Electric AF-600 FP Series Drive Error Codes
System Monitoring and Alarm Types
General Electric AF-600 FP series drives monitor many system performance indicators such as input power, output, and motor factors. An alert or alarm does not necessarily indicate a problem with the drive itself. In most cases, it indicates fault conditions arising from areas monitored by the input voltage, motor load or temperature, external signals, or the internal logic of the frequency converter. It is important to investigate areas other than the drive mentioned in the alarm or alert.
- Alerts: An alert is given when an alarm condition is approaching or an abnormal operating condition exists and could cause the drive to give an alarm. The alert is automatically cleared when the abnormal condition is resolved.
- Alarms: An alarm is given when the drive stops operation to prevent damage to the drive or system, i.e., the drive is disabled. The motor coasts to a stop. The drive logic continues to operate and monitor the drive status. The drive can be reset and made ready for operation after the fault condition is cleared.
Summary of Error Codes:
- Error/Warning Code 1 - 10 Volt Low: (More details >>)
- Error/Warning Code 2 - Live Zero Error: (More details >>)
- Error/Warning Code 4 - Main Phase Loss: (More details >>)
- Error/Warning Code 5 - DC Link Voltage High: (More details >>)
- Error/Warning Code 6 - DC Link Voltage Low: (More details >>)
- Error/Warning Code 7 - DC Over Voltage: (More details >>)
- Error/Warning Code 8 - DC Under Voltage: (More details >>)
- Error/Warning Code 9 - Inverter Overloaded: (More details >>)
- Error/Warning Code 10 - Motor Electronic Thermal Overload Temperature: (More details >>)
- Error/Warning Code 11 - Motor Thermistor Over Temperature: (More details >>)
- Error/Warning Code 12 - Torque Limit: (More details >>)
- Error/Warning Code 13 - Over Current: (More details >>)
- Error/Warning Code 14 - Ground Fault: (More details >>)
- Error/Warning Code 15 - Hardware Mismatch: (More details >>)
- Error/Warning Code 16 - Short Circuit: (More details >>)
- Error/Warning Code 17 - Control Word Timeout: (More details >>)
- Error/Warning Code 18 - Initialization Failed: (More details >>)
- Error/Warning Code 23 - Internal Fan Failure: (More details >>)
- Error/Warning Code 24 - External Fan Failure: (More details >>)
- Error/Warning Code 29 - Drive Over Temperature: (More details >>)
- Error/Warning Code 30 - Motor Phase U Missing: (More details >>)
- Error/Warning Code 31 - Motor Phase V Missing: (More details >>)
- Error/Warning Code 32 - Motor Phase W Missing: (More details >>)
- Error/Warning Code 33 - Sudden Current Error: (More details >>)
- Error/Warning Code 34 - Field Communication Error: (More details >>)
- Error/Warning Code 35 - Option Fault: (More details >>)
- Error/Warning Code 36 - Main Fault: (More details >>)
- Error/Warning Code 38 - Internal Error: (More details >>)
- Error/Warning Code 39 - Heat Sink Sensor: (More details >>)
- Error/Warning Code 40 - Overload of Digital Output Terminal 27: (More details >>)
- Error/Warning Code 41 - Overload of Digital Output Terminal 29: (More details >>)
- Error/Warning Code 42 - Overload of Digital Output at X30/6: (More details >>)
- Error/Warning Code 42 - Overload of Digital Output at X30/7: (More details >>)
- Error/Warning Code 45 - Ground Fault 2: (More details >>)
- Error/Warning Code 46 - Power Card Supply: (More details >>)
- Error/Warning Code 47 - 24V Supply Low: (More details >>)
- Error/Warning Code 48 - 1.8V Supply Low: (More details >>)
- Error/Warning Code 49 - Speed Limit: (More details >>)
- Error/Warning Code 50 - Auto Tuning Calibration Failed: (More details >>)
- Error/Warning Code 51 - Auto Tuning U nom and I nom Check: (More details >>)
- Error/Warning Code 52 - Auto Tuning Low I nom: (More details >>)
- Error/Warning Code 53 - Auto Tuning Motor Too Large: (More details >>)
- Error/Warning Code 54 - Auto Tuning Motor Too Small: (More details >>)
- Error/Warning Code 55 - Auto Tuning Parameter Out of Range: (More details >>)
- Error/Warning Code 56 - Auto Tuning Interrupted by User: (More details >>)
- Error/Warning Code 57 - Auto Tuning Timeout: (More details >>)
- Error/Warning Code 58 - Auto Tuning Internal Error: (More details >>)
- Error/Warning Code 59 - Current Limit: (More details >>)
- Error/Warning Code 60 - External Lockout: (More details >>)
- Error/Warning Code 62 - Output Frequency Reached Maximum Limit: (More details >>)
- Error/Warning Code 64 - Voltage Limit: (More details >>)
- Error/Warning Code 65 - Control Card Over Temperature: (More details >>)
- Error/Warning Code 66 - Heat Sink Temperature Low: (More details >>)
- Error/Warning Code 67 - Option Configuration Changed: (More details >>)
- Error/Warning Code 69 - Power Card Temperature: (More details >>)
- Error/Warning Code 70 - Illegal Drive Configuration: (More details >>)
- Error/Warning Code 76 - Power Unit Installation: (More details >>)
- Error/Warning Code 79 - Illegal PS Configuration: (More details >>)
- Error/Warning Code 80 - Drive Initialized to Default Value: (More details >>)
- Error/Warning Code 91 - Analog Input 54 Wrong Settings: (More details >>)
- Error/Warning Code 92 - No Flow: (More details >>)
- Error/Warning Code 93 - Dry Pump: (More details >>)
- Error/Warning Code 94 - End of Curve: (More details >>)
- Error/Warning Code 95 - Broken Belt: (More details >>)
- Error/Warning Code 96 - Start Delayed: (More details >>)
- Error/Warning Code 97 - Stop Delayed: (More details >>)
- Error/Warning Code 98 - Clock Error: (More details >>)
- Error/Warning Code 201 - Fire Mode Active: (More details >>)
- Error/Warning Code 202 - Fire Mode Limits Exceeded: (More details >>)
- Error/Warning Code 203 - Missing Motor: (More details >>)
- Error/Warning Code 204 - Locked Rotor: (More details >>)
- Error/Warning Code 243 - Brake IGBT: (More details >>)
- Error/Warning Code 244 - Heat Sink Temperature: (More details >>)
- Error/Warning Code 245 - Heat Sink Sensor: (More details >>)
- Error/Warning Code 246 - Power Card Supply: (More details >>)
- Error/Warning Code 247 - Power Card Temperature: (More details >>)
- Error/Warning Code 248 - Illegal PS Configuration: (More details >>)
- Error/Warning Code 250 - New Spare Parts: (More details >>)
- Error/Warning Code 251 - New Type Code: (More details >>)
+ Ge VFD User Manuals >>
+ Ge AF-6 (600,650..) Fault index >>
+ Ge AF-6 (600,650..) Fault Codes 1 >>
+ Ge AF-6 (600,650..) Fault Codes 2 >>
+ Ge AF-6 (600,650..) Fault Codes 3 >>
+ Ge AF-6 (600,650..) Fault Codes 4 >>
+ General Electric 2. Main page >
+ VFD Homepage >