GD300-02
GD300-02
GD300-02 is a through-wall AC drive designed to reduce exposure of the cooling arrangement to cotton fluff, dust and oil in textile environments. INVT's industrial-automation catalogue gives a three-phase 380 V (-15%)–440 V (+10%) input and a 7.5–55 kW range. That is the catalogue coverage, not the output current of a particular frame; read its full label.
Why the mounting differs
The flange arrangement places the heat-dissipating side through the panel or wall, reducing contact between dirty process air and the electronics. INVT lists operation in 50 °C ambient conditions, a shared DC-bus option and induction/synchronous motor compatibility. Cabinet ventilation and sealing remain installation-design issues; replacing only the drive frame does not reproduce the whole protective arrangement.
Replacement or new installation
Check the wall cut-out, flange dimensions, motor type, complete power code and whether a shared DC bus is wired. GD350 is a separate general-purpose drive, while GD350-02 is a newer through-wall range. Similar names do not establish identical dimensions or parameters.
Manuals and documents
Find the documentation topics for this equipment group on INVT VFD Documents.
Use INVT user manuals, checking the complete model code.