6ES7 157-0AA00-0XA0
Siemens 6ES7 157-0AA00-0XA0 – IM 157 PROFIBUS DP/PA Link Interface Module
6ES7 157-0AA00-0XA0 is a SIMATIC IM 157 interface module used to build a DP/PA Link. Manufactured by Siemens, it forms the central communication interface between PROFIBUS PA field instruments and the higher-level control system. It is particularly relevant when maintaining communication between a PLC and process instruments, or identifying a replacement for an existing station.
The compact article number is 6ES7157-0AA00-0XA0. When selecting a module, check the 0AA00 designation as well as the IM 157 family name. Versions within this family differ in areas such as redundancy support and environmental specifications.
Its role within a DP/PA Link
The IM 157 operates together with suitable DP/PA couplers. The resulting link acts as a slave on the PROFIBUS DP side and as a master on the PA side, allowing field-device data to reach the SIMATIC S7 system.
The IM 157 and the DP/PA coupler are separate components. The interface module manages communication, while the coupler provides the physical PA connection and field-bus power. During automation maintenance, this distinction helps separate a PA power problem from a communication fault on the upstream network.
Technical characteristics
Manufacturer / family: Siemens SIMATIC IM 157
Article number: 6ES7 157-0AA00-0XA0
Function: DP/PA Link interface module
Supply: 24 V DC, four-pole screw connection
PROFIBUS DP connector: 9-pin Sub-D
DP side: Up to 12 Mbit/s, subject to system restrictions.
PA side: 31.25 kbit/s
Module width / height: 40 / 125 mm
Specified maximum mounting depth: 130 mm
Redundant operation in an H system: Not supported.
The classic DP/PA Link arrangement accommodates up to 5 DP/PA couplers and a total of 31 PA field devices per link. Actual capacity can be limited by coupler output current, instrument consumption and the amount of data transferred. Using five couplers does not create five independent allocations of 31 devices.
Associated DP/PA couplers
Siemens documentation for this generation identifies the 6ES7 157-0AC00-0XA0 standard DP/PA coupler and the 6ES7 157-0AD00-0XA0 Ex [i] coupler. The installed coupler's complete article number matters because it determines the field connection and the electrical conditions of the application.
Ex [i] applications require the appropriate coupler and field circuit to be assessed together; the IM 157 alone does not provide intrinsic safety. When replacing a coupler or researching connection modules, physical resemblance is insufficient evidence of compatibility.
The important difference between 0AA00 and 0AA80
6ES7 157-0AA00-0XA0 cannot be used for redundant operation in an H system. Siemens lists the 0AA80 separately as a redundant IM 157-2 version. An installed module in a redundant IM pair therefore cannot be replaced with the 0AA00 simply because both carry the IM 157 designation.
The −25 to +60 °C range specified for the 0AA80 should also not be presented as a specification for the 0AA00. Firmware update facilities and expanded diagnostic features documented for later versions require the same care. When comparing communication interfaces, use the full article number.
Mounting, power and cabling
This generation of DP/PA Link uses an S7-300 mounting rail and standard bus connections. Cabinet space must include the couplers as well as the IM 157. Allow room for the front-mounted Sub-D connector and the cable bend.
During fault investigation, check the power supply, connections between modules, shield continuity and grounding arrangement separately. An energized IM 157 does not, by itself, confirm that the PA segment is receiving the correct supply.
Project checks and communication speed
Before changing an existing station, record the module selection in STEP 7, the PROFIBUS address and the field-device configuration. Compare the hardware entry in the project with the article number on the label, and preserve the original project files and instrument parameters. These records make configuration differences easier to trace after replacement.
The 12 Mbit/s figure is not an unconditional operating speed for every system. Siemens specifies a 1.5 Mbaud restriction when a CP 443-5 Extended 6GK7443-5DX03 is used with this IM 157 generation in an S7-400H/FH system, referring to FAQ 11168943 for the remedy. This system-level note does not establish support for using the 0AA00 as part of a redundant IM pair.
Check the field instrument's interface
A pressure, temperature, level or flow instrument needs the appropriate PROFIBUS PA interface to participate in this communication arrangement. A transmitter measuring the same process variable through a conventional 4–20 mA output requires a different connection. In that case, assess a suitable analog input module or conversion device; the IM 157 does not act as a direct analog measurement input.
PDF manuals and technical documentation
Browse our Siemens ET200 manuals and PDF documentation page for related documents. When selecting a manual, check for IM 157, DP/PA Link and 6ES7 157-0AA00-0XA0 together. A similar number printed on a manual cover may be the document's ordering code; the list of covered hardware must also be checked.
Editor's note: Record the IM 157 label, the adjacent coupler article numbers and the existing project information before selecting a replacement. The redundancy difference between 0AA00 and 0AA80 is particularly important and can easily be missed when two modules look similar.
Related product groups
For other parts of the control cabinet, explore ET200 power supply modules, power distribution modules, terminal blocks, additional modules and other network interfaces. These categories introduce general product groups; they are not a list of accessories approved for direct use with the IM 157.
Explore: Siemens ET200 | About ET200 | Siemens S7 PLC products