6ES7 131-4BD00-0AA0

6ES7 131-4BD00-0AA0

Series: Siemens SIMATIC DP / ET 200S

Category: ET 200S Digital Input Module – 4DI 24 V DC Standard

Description

6ES7 131-4BD00-0AA0 is a four-channel 24 V DC digital input module for the Siemens SIMATIC ET 200S distributed I/O system. This Standard, or ST, electronic module acquires status signals from switches and electrically compatible proximity sensors.

Within the ET 200 product family, the electronic module has a width of 15 mm. When selecting a replacement digital input module, compare the complete order number, terminal base and project configuration.

Device Function and Applications

The module transfers on/off information from pushbuttons, limit switches and suitable electronic sensors to the control system. Machine position, part presence and auxiliary equipment status can then be processed by the connected controller. Clear identification of each field device and its assigned channel makes signal tracing easier during maintenance of an automation system.

Select sensors according to the 24 V DC nominal input design. The output circuit and off-state current matter alongside the sensor’s operating voltage. If the indication at the field device differs from the PLC status, trace the signal from the sensor output through to the module terminal.

Technical Specifications

Order number: 6ES7131-4BD00-0AA0
System: SIMATIC ET 200S
Module class: Standard, ST
Digital inputs: 4 DI
Rated input voltage: 24 V DC
Signal “1” input range: +15 to +30 V DC
Signal “0” input range: −30 to +5 V DC
Input current at signal “1”: Typically 7 mA at 24 V
Input delay: Typically 3 ms in both directions; 2–4.5 ms
Delay adjustment: Not parameterizable
Status indication: Green LED per channel
Module diagnostic functions: None
Electronic module dimensions: 15 × 81 × 52 mm; width × height × depth
Weight: Approximately 35 g
Manufacturer packaging: 5 modules per packaging unit

The signal thresholds describe the voltages recognized as “0” or “1” and should be distinguished from the nominal supply rating. A voltage between +5 V and +15 V is not a suitable operating point for a definite logic state. Investigate signals remaining in this region because of poor connections or voltage drop.

The manufacturer’s five-module packaging description does not establish the sales quantity at Otomasyon AVM. Check the individual listing for quantity, scope of delivery and whether a terminal base is included.

Sensor Connections and Off-State Current

Siemens documentation supports the connection of two-wire proximity sensors and specifies a maximum permissible off-state current of 1.5 mA. Check this value when selecting an electronic sensor. A sensor can operate mechanically as expected while producing an unsuitable electrical condition at the input.

When investigating intermittent signals, inspect the sensor connectors, cable joints and terminal contacts. The sensor’s own indicator does not establish that its signal has reached the input module.

Terminal Module and Installation

The electronic module plugs into a suitable ET 200S terminal module. A Siemens station example pairs this product with the TM-E15S24-01 / 6ES7193-4CB20-0AA0. The system manual also describes other bases for different connection arrangements. Select the terminal block according to the actual wiring requirements.

Similar terminal base names can represent different auxiliary terminal and potential distribution arrangements. Verify terminal assignments against the correct diagram when replacing connection components. The electronic module dimensions of 15 × 81 × 52 mm do not describe the complete installation with its base.

Power Supply and Common Connections

Assess the field power supply together with the appropriate station ET 200 power module and terminal arrangement. If several inputs in the same potential group disappear together, first check their common voltage, connections and power distribution.

Measurements must use the correct reference. Trace the project’s M connection, protective conductor and grounding arrangement individually. Voltage drops occurring while loads switch may remain unnoticed during a single measurement under steady conditions.

Programming and Input Addresses

The four channel states reach the PLC program through addresses assigned in the hardware configuration. The specified address space is 4 bits with supported packing or 1 byte without packing. Read the channel addresses from the actual station sequence and configuration.

The input module acquires field status. The station interface determines the PROFIBUS or PROFINET connection used to transfer data to the controller. Verify the relevant ET 200 communication configuration against the complete interface order number.

LED Indication and Fault Investigation

The green channel LEDs indicate input status. The data sheet specifies no module diagnostic functions for this Standard module. A channel LED should therefore be interpreted as a status indicator rather than a separate indication of wire break or sensor failure.

An input reading “0” does not distinguish a normally inactive sensor from a missing supply or interrupted signal path. Compare field voltage, the channel LED and the PLC input bit alongside the interface and power module indications.

Maintenance and Commissioning Recommendations

Supply check: Verify the potential group voltage, then compare the sensor output and module input in both sensor states.

Address check: If the channel LED changes but the program value does not, inspect the input address, station module sequence and configured hardware order number.

Timing check: Communication and PLC program cycle time add to the input delay. For short pulses, assess signal duration across the complete acquisition path.

Replacement check: 6ES7131-4BD00-0AA0, similarly named High Feature products and other revisions have separate order numbers. Confirm terminal and project compatibility before selecting a replacement.

Editor’s Recommendations

A useful practical check is to observe sensor output voltage, the channel LED and the PLC input bit together. Differences between these three observations help narrow the investigation to field wiring or configuration. Checking terminal base contacts and the common supply before replacing the electronic module can prevent unnecessary component changes.

Related Topics

Explore ET 200 additional modules, SIMATIC S7 products and the Siemens S7 PLC category for related equipment groups.

+ Siemens ET 200 PLC user manuals (PDF documentation page)

+ Siemens ET 200S system manual covering 6ES7 131-4BD00-0AA0 (07/2003, English PDF; section 12.3)

+ Siemens ET 200 general product catalogue (PDF file; check the order number for model-specific information)

++ Siemens Automation Main Page >

++ Siemens Automation Contact (for Otomasyon AVM)

++ About Siemens ET 200 PLC >

Reminder: Availability, quantity and scope of delivery for Siemens 6ES7 131-4BD00-0AA0 and other SIMATIC PLC modules must be checked against the individual listing. Some devices are used products; consider their stated condition before purchasing. Products will not be restocked once sold out. This page provides general information; consult the manufacturer’s documentation for definitive specifications and application requirements.

Note: Manuals, commissioning explanations and troubleshooting suggestions on this page are non-binding and may be updated or improved. The Otomasyon AVM Community welcomes practical experience and usage suggestions. Please contact us to share technical observations or corrections.