6ES7 138-4DB01-0AB0
Siemens Main Menu › SIMATIC S7 › ET 200 Modules
Siemens 6ES7 138-4DB01-0AB0 — ET 200S 1SSI Absolute Encoder Module
6ES7 138-4DB01-0AB0 is an ET 200S 1SSI absolute encoder interface in the Siemens ET 200 distributed automation family. It transfers encoder position information to the control system. Consider it among ET 200 technology modules when a project requires position feedback.
Technical features and operating modes
Channel: 1 SSI. Encoder formats: 13, 21 or 25 bits; Gray or binary coding. Supply: 24 V DC. Width: 15 mm. Signals: RS422 differential SSI data and clock. Standard mode provides latch and comparison functions; Fast Mode reduces the function set for faster value transfer.
Also review ET 200 positioning modules when defining the application. Reading position and driving an axis are different tasks. Assess the control algorithm, drive and mechanics together. For applications based on counting incremental encoder pulses, compare the appropriate ET 200 counter modules.
Station and terminal selection
The Siemens manual identifies TM-E15S24-01 and TM-E15S26-A1 terminal options. Check the complete type when selecting ET 200 terminal blocks. For field connections and connection modules, use the cabinet drawing, cable labels and module terminal assignment together.
Siemens lists this product as supporting isochronous operation on PROFIBUS DP. The controller, station interface and project settings must also support the intended configuration. When reviewing PROFIBUS and PROFINET interface options, verify the installed interface module’s complete order number; a network name alone does not establish compatibility.
Five checks before selection
1. Product and project: Match the 4DB01 designation on the label to the hardware configuration. When consulting the ET 200 system and product family guide, keep the ET 200S station and its components clearly identified.
2. Encoder data: Record the encoder model, telegram length, coding and position scaling. Back up the working project. A number appearing on the operator display is not sufficient evidence of a correct measurement.
3. Power and potentials: Review the ET 200 power supply modules and power distribution and potential groups. Assess encoder supply requirements separately from the electrical characteristics of its data signals. Identify wires from documentation, rather than colour alone.
4. Functions and timing: Check whether the existing project selects standard mode or Fast Mode. When planning ET 200 digital input modules for auxiliary sensors, distinguish event triggering from general status monitoring. Consult both encoder and Siemens documentation for cable length and clock settings.
5. Commissioning: With the machine in a safe state, compare the reported position at several known mechanical points. Check direction, zero crossing and the reading after a power cycle. Confirm whether the terminal base is included before purchasing.
Editor’s Note
A smoothly changing position value does not by itself prove that the reading matches the mechanics. Keep the encoder label, project parameters and readings at known positions in the maintenance record. This makes scaling and direction errors easier to identify during a later replacement.
PDF manuals and wiring: Visit the Siemens ET 200 user manuals and PDF documentation page. Use the 1SSI chapter of ET 200S Technological Functions and check the order numbers covered by the document. The DB01 reference verified here is the Japanese 06/2002 edition, A5E00216913-02. Do not automatically apply every parameter from a newer manual to this version.
Related Topics
Technology Modules · Positioning Modules · Counter Modules · Terminal Blocks