Gemo AR2-G1-24VDC-12D2A – 12 Digital Input / 2 Analog Input / 10 Relay Output I/O Expansion Module

Gemo AR2-G1-24VDC-12D2A is a DIN-rail mounted I/O expansion module for the Gemo AR2 PLC / Smart Relay family. It is designed to increase the number of field inputs and outputs available to a compatible AR2 controller.

This version operates from an 18…32 VDC supply and provides 12 digital inputs, 2 × 0-10 V analog inputs, 10 relay outputs and one PTC temperature sensor input.

Important: The AR2-G1 is not a standalone PLC. It must be used with a compatible Gemo AR2-A or Gemo AR2-P CPU. The main controller executes the Ladder program, while the AR2-G1 provides additional physical I/O.

Gemo AR2-G1-24VDC-12D2A technical specifications

• Product type: I/O expansion module for Gemo AR2 PLC / Smart Relay

• Power supply: 18…32 VDC

• Digital inputs: 12

• Analog inputs: 2 × 0-10 VDC

• Analog outputs: Not available

• Digital outputs: 10 relay outputs

• Relay contact rating: Maximum 250 VAC / 2 A with resistive load

• PTC input: 1 × PTC temperature sensor input

• Status indication: Front-panel LED indicators for I/O and module status

• Mounting: DIN-rail mounting

• Protection class: IP20

AR2-G1 I/O addressing

When the AR2-G1-24VDC-12D2A is connected to the AR2 control system, its additional channels are assigned as follows:

• Digital inputs: DIn15…DIn26

• Analog inputs: AnIn3 and AnIn4

• PTC input: PTC2

• Digital outputs: DQ11…DQ20

In the 12D2A configuration, DIn27 and DIn28 are not used and remain permanently OFF.

What does 12D2A mean?

The 12D2A designation identifies the I/O configuration of the module: 12 digital inputs and 2 analog inputs.

The two analog channels accept 0-10 VDC signals and are available to the AR2 program as AnIn3 and AnIn4.

Analog input specifications

• Input range: 0-10 VDC

• Maximum analog input voltage: 16 VDC

• A/D resolution: 10 bit

• Sampling period: 100 ms

• Analog ground: Separate analog ground

For analog measurement applications, signal cables should be kept away from motor and power wiring whenever possible. Appropriate shielding and grounding should be used.

Relay outputs

The AR2-G1-24VDC-12D2A uses mechanical relay outputs. Ten additional relay channels are available as DQ11…DQ20.

Each relay output is rated up to 250 VAC / 2 A for resistive loads. Inductive loads such as contactor coils, solenoids and valves should be connected with suitable suppression components according to the application.

This model should not be confused with the AR2-G1-24VDC-12D2A-TR, which uses PNP transistor outputs instead of relay contacts.

Digital input characteristics

• OFF level: 0…2 VDC

• ON level: 10…32 VDC

• Maximum input voltage: 32 VDC

• Input common: Negative common, suitable for PNP / Totem Pole signals

• Digital input filter time: Minimum 8 ms

• Fast input ON time: Minimum 1.25 ms

• Fast input OFF time: Minimum 1.25 ms

• Fast input frequency: Maximum 400 Hz at 50% duty cycle

PTC temperature sensor input

A dedicated 2-wire PTC sensor input is provided. The extension-module temperature channel is identified as PTC2 within the AR2 system.

The supported PTC measurement range is approximately -50°C to +150°C.

Compatible Gemo AR2 controllers

The AR2-G1-24VDC-12D2A is designed for use with:

• Gemo AR2-A-14D series

• Gemo AR2-A-12D2A series

• Gemo AR2-P series

RS-485 expansion connection

The AR2-G1 communicates with the main AR2 CPU through an RS-485 interface.

A twisted and shielded 2-core, 24 AWG cable is recommended. The communication line is wired A ↔ A and B ↔ B. Depending on cable length and installation conditions, RS-485 termination may be required.

Programming and control functions

The AR2-G1 does not contain the main programmable CPU. Ladder logic, timers, counters, PID functions and other automation logic are executed by the connected AR2 controller.

The module simply makes its additional digital inputs, analog inputs, PTC channel and relay outputs available to the main PLC program.

For applications involving PID control or servo and stepper motion systems, the capabilities of the main AR2 CPU should therefore be considered rather than the expansion module itself.

HMI connection

An operator panel is used as part of the complete AR2 system and is not connected as an independent function of the AR2-G1 module. Compatible display solutions are available under HMI for Gemo PLC.

Installation in industrial control panels

The AR2-G1 can be installed in automation panels containing equipment such as variable frequency drives and frequency inverters.

Signal and analog wiring should be separated from motor and high-current cables whenever possible. Correct grounding and shielding practices should be followed, and suitable EMC filtering should be used where required.

Gemo AR2 software, manuals and related information

• Gemo AR2 PLC User Manual – English PDF manual

• GEMO Ladder Editor programming software – Version 2.4

• Gemo price list

• Gemo contact information

• Gemo Electronic main page

• PLC product groups

Important safety notice

Installation, wiring and commissioning of the Gemo AR2-G1 expansion module and the associated AR2 PLC / Smart Relay system should be carried out only by qualified technical personnel.

Disconnect power before wiring, removing or replacing the module. Use correctly rated conductors, suitable protective devices and the wiring methods specified for the AR2 system.

For technical assistance, contact gemo@otomasyonavm.com or visit the Gemo contact page.

Write a review

Note: HTML is not translated!
Bad Good

Gemo AR2-G1-24VDC-12D2A

  • 110.00USD

  • Ex Tax: 110.00USD

Related Products

H2U-0808ERN

H2U-0808ERN

inovance H2U plc Input ve Output Module8 digital input 8 digital  output  remote I/O Modul..

253.00USD Ex Tax: 253.00USD

EXLC-1410-R-B

EXLC-1410-R-B

DERELL EXLC-1410-R-B is a PLC digital I/O module. It combines digital field inputs and control outpu..

100.00USD Ex Tax: 100.00USD

EXLC-1410-R-A

EXLC-1410-R-A

DERELL EXLC-1410-R-A is a PLC digital I/O module. It combines digital field inputs and control outpu..

100.00USD Ex Tax: 100.00USD

EXLC-1210-2I-R-A

EXLC-1210-2I-R-A

DERELL EXLC-1210-2I-R-A is a PLC digital I/O module. It combines digital field inputs and control ou..

100.00USD Ex Tax: 100.00USD