Delta HMI Files

Delta HMI Files is a model and document selection guide for DOP touch panels, TP text/PLC panels, HMC motion controllers and their software and connections. Identify the complete code first, then select the panel family, engineering tool, communication and supporting hardware together.

For catalogues, installation sheets, pin diagrams and software manuals, open the Delta HMI PDF archive. This page directs you to the appropriate family; detailed comparisons are on the related model pages. Match documents by complete model, hardware revision, actual language and edition.

Which Delta HMI family do you need?

DOP-A, DOP-AE and DOP-AS are legacy Screen Editor families. STN, FSTN and TFT displays, housings, serial channels and expansion vary by model. An expansion listed for AE is not automatically compatible with A or AS.

DOP-B and DOP-W are fixed operator-panel families; DOP-100 is a later family with Basic, Standard and Advanced options. Equal screen size does not establish equal resolution, cutout, Ethernet or serial hardware.

DOP-H07 and DOP-107H are handheld panels. Cable length, MPG, physical keys, three-position switch, emergency-stop contacts and connector suffixes determine selection. Review handheld use and cable connections rather than treating overall dimensions as panel cutouts.

TP text panels, TP04P and TP70P are separate model groups. Text/keypad design, built-in PLC, local I/O and weighing functions depend on the complete code. Do not transfer relay, transistor or load-cell specifications between models.

HMC07 and HMC08 combine HMI and motion control. Consider the servo network, motion program, compatible remote I/O and cable together. They do not have the same control role as a DOP panel displaying data from an external PLC.

Which programming software is used?

DOP-A / DOP-AE / DOP-AS: the Screen Editor / ScrEdit 1.05 generation is the legacy reference. Earlier DOP-B projects may use Screen Editor 2.00 or DOPSoft 2.00; DOP-H07 and DOP-W also require the appropriate DOPSoft target/version. Record the installed panel OS/firmware and project target together.

DOP-100 / DOP-107H: legacy projects use DOPSoft 4. DOPSoft 4 maintenance ended on 23 October 2023; Delta recommends DIAScreen. Check support for the exact HMI target in the selected release. Opening or converting a project in a newer tool does not guarantee download support for the old panel.

TP screen projects: use the appropriate TPEditor generation. On compatible TP models with a built-in PLC, screen and PLC projects are separate; select WPLSoft / ISPSoft according to model support for the PLC portion. For HMC, the appropriate DOPSoft HMC target covers screen, PLC logic and motion functions; a screen backup alone is not the complete control project.

Use manufacturer release and support records when finding legacy tools. For DOPSoft 2.00 for DOP-B, Delta directs users to its official support request route. Do not assume every legacy installer remains available in the current download centre.

Cables, expansion and power

HMI modules and accessories separates mounting/power connections, digital I/O expansion and Ethernet expansion. Verify the module code and supported panel generation. Having Ethernet does not establish all network functions available on another Ethernet-equipped panel.

Select programming and HMC cables, communication accessories and remote I/O modules by both ends, electrical standard, pin assignments and protocol. USB, RS-232, RS-422/485, Ethernet and DMCNET are different interfaces. Choose shared power supplies for the panel voltage, total load and cable voltage drop.

For HMI starter kits, check the panel, cable, power supply and software target as one configuration. A kit is not automatically compatible with every display size or generation.

Replacing an installed panel

Compare the full label and suffixes, working project, editor version, display resolution, mounting dimensions, power and PLC connection. Back up recipes, alarms, calibration and network settings while the old unit works. Convert a copy and check physical keys, MPG, macros and communication-loss behaviour under controlled conditions.

Editor’s note

Start with the full label rather than screen size. A final letter or digit may change ports, housing, cable or hardware options.

Keep the software name and version with the project. HMI source, PLC program and recipe backups are different items; opening one file is not a complete recovery test.

Check both cable ends, serial standard and supply conductors without power. A connector fitting does not establish compatibility; handheld emergency-stop contacts need separate verification.

For display or touch faults, inspect 24 V under load, connectors, cable, contamination/moisture and mounting pressure first. Preserve the working project before changing software.

Separate TP screen/PLC functions and HMC motion/I/O functions. One panel file may not contain everything needed to recover the machine.

Change one item at a time during migration. Test a known PLC value, keys, alarms and recipes in sequence, keeping the working original for recovery.

Related topics

Delta HMI PDF files · HMI modules and accessories · Programming and HMC cables · HMI power supplies

Official software and support addresses

Delta download centre · DIAScreen information · Manufacturer support route for DOPSoft 2.00 · DOPSoft 4 maintenance-end advisory